Problem Possible Causes What To Do
Salty tasting water
Insufficient backwash and Increase backwash time. See the
Service: Regeneration
after installation
rinse time and
Heavy Duty Backwash
section.
Low water pressure Check pressure; should be minimum 20 psi.
Restricted drain hose Clean and reconnect hose.
Resin beads showing
Cracked distributor Call for service.
up in drinking water
and sink
Sounds you might hear
Running water from the unit into This is normal.
a drain
Water has air bubbles
Air in system after installation Will go away after it runs for a while.
and is cloudy
Error Code on control
Wiring may have worked loose in Unplug transformer.
control
Remove control cover, release clips on side.
Check for loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.
Reassemble control cover.
Plug in Transformer.
Wait six minutes for Error Code to reappear.
If Error Code reappears call for service.