EasyManuals Logo
Home>GiBiDi>Control Unit>SC24

GiBiDi SC24 User Manual

GiBiDi SC24
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
UK
SC24
Descrizione
DIP 1
DIP 2
DIP
I Start pulse:
:
II Start pulse:
III Start pulse
IV Start pulse:
OFF
OFF
Stato Funzione
STEP-BY-STEP
WITH STOP
FUNCTION PROGRAMMING (DIP SWITCH - Sw1)
The settings are stored during the rest phase (gate closed).
OPEN
STOP (will not reclose automatically)
CLOSE
OPEN
DIP 1
DIP 2
During opening does not receive other Start commands after the first one; during
Pause subsequent Start commands reload the pause time.
I Start pulse: OPEN
Subsequent Start pulses: Uninfluential
Pause from opening limit switch
Start pulse during pause: Reloads the pause time (if DIP 6 ON)
or CLOSES (if DIP 6 OFF)
Subsequent Start pulse: OPEN
OFF
ON
CONDOMINIUM
DIP 1
DIP 2
I Start pulse:
II Start pulse:
IV Start pulse:
ON
OFF
STEP-BY-STEP
OPEN
CLOSE
OPEN
DIP 4
Enables the safety device TEST before activating the opening and closing cycle.
The test consists of temporarily cutting the power to the devices and checking proper
switching of the contact.
The cycle can only start if the devices work perfectly, if not, three prolonged flashes
indicate the fault.
ON
SAFETY DEVICE
TEST
DIP 1
DIP 2
DIP 3
Enables pre-flashing of 2 seconds before motor activation during opening and closing.
Disables pre-flashing.
ON
ON
ON
OFF
DEAD MAN
PRE-FLASHING
DIP 8
Reduces the pause time to 3 seconds after intervention of one of the photocells.
Disables the fast closing function.
Not used.
Not used.
ON
OFF
FAST CLOSING
DIP 10
Supplies the LEDs (which will come on depending on the respective contact).
After proper installation, the LED power supply can be deactivated to save energy.
Disables the warning LED power supply.
ON
OFF
LED POWER
SUPPLY
Disables the safety device test.
OFF
DIP 5
When the photocell is intercepted during both opening and closing, the gate motion is
locked until the photocell is freed. Subsequently, there is always an opening phase.
ON
PHOTOCELL DURING
OPENING
Disables the photocell function during opening.
OFF
DIP 7
Enables deceleration during both opening and closing when the respective limit
switch is intercepted. The deceleration speed is adjusted with the trimmer TR3
SLOW. This function provides for use of 4 magnets (see drawing 2).
ON
DECELERATION
Disables the deceleration function. Only 2 magnets are required (see drawing 2).
OFF
DIP 9
ON
OFF
If Start button is held down:
If Pedestrian button is held down:
In this function safety devices and decelerations are not active.
OPEN
CLOSE
DIP 6
Enables automatic closing after the pause time adjustable with the trimmer TR5
PAUSE between 2 and 215 seconds.
Disables automatic closing.
ON
OFF
AUTOMATIC
CLOSING

Other manuals for GiBiDi SC24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GiBiDi SC24 and is the answer not in the manual?

GiBiDi SC24 Specifications

General IconGeneral
BrandGiBiDi
ModelSC24
CategoryControl Unit
LanguageEnglish

Related product manuals