EasyManuals Logo
Home>Glow-worm>Boiler>swift flow 80

Glow-worm swift flow 80 Installation Instructions

Glow-worm swift flow 80
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
221132B
1 G e n e r a l
1.4 Requirements
The installation of this boiler must be carried out by a
competent person in accordance with the rules in force in
the countries of destination.
Manufacturer’s instructions, supplied.
Manufacturer’s instructions must not be taken as
overriding statutory requirements.
1.5 Data Label
The data label is at the top right hand side of the
inner case.
1.6 Data
HONEYWELL
S.I.T.
Testing and Certification
This boiler is tested and certificated for safety and
performance. It is therefore important that no alteration
is made to the boiler, without permission, in writing,
from Hepworth Heating Ltd.
Any alteration not approved by Hepworth Heating Ltd.,
could invalidate the certification, boiler warranty and
may also infringe the current issue of the Statutory
Requirements, see Section 1.4.
CE Mark
This boiler meets the requirements of Statutory
Instrument No. 3083 The Boiler (Efficiency)
Regulations, and therefore is deemed to meet the
requirements of Directive 92/42/EEC on the efficiency
requirements for new hot water boilers fired with liquid
or gaseous fuels.
Type test for purposes of Regulation 5 certified by:
Notified body 0087.
Product/production certified: Notified body 0087.
The CE mark on this appliance shows compliance with:
1. Directive 90/396/EEC on the approximation of the
Laws of the Member States relating to appliances
burning gaseous fuels.
2. Directive 73/23/EEC on the harmonization of the
laws of the Member States relating to electrical
equipment designed for use within certain voltage limits.
3. Directive 89/336/EEC on the approximation of the
Laws of the Member States relating to electromagnetic
compatibility.
This boiler will be fitted with either a Honeywell or SIT
Gas Valve. The valve used can be identified as shown.
Materials and equipment should be fit for their purpose
and of suitable quality and workmanship.
1.2 Important Notice
This boiler is for use only on G20 gas.
1.3 Sheet Metal Parts
WARNING. When installing or servicing this boiler
care should be taken when handling the edges of sheet
metal parts to avoid any possibility of personal injury.
Weight 47.2kg (104lb)
Gas connection Rc
1
/
2
(
1
/
2
in BSP)
Heating Flow and Return 22mm compression
D.H.W Inlet and Outlet
15mm compression (Ball valves are incorporated in
water and gas connections plus a drain point on all water
connections).
Safety Valve preset 3bar (43.5lbf/in
2
)
Safety Valve Discharge 15mm compression
Water Content 1.74Litre (0.38gall)
Expansion Vessel 8Litre
Capacity (1.76gal)
Heating Cold Fill 0.7bar
Pressure (10.1lbf/in
2
) minimum
D.H.W Working Pressure 0.5 to 10bar
(7.25 to 188lbf/in
2
)
Maximum Heating System 119Litre (26.2gall)
Water Content (Larger systems will require
an additional expansion
vessel, refer to Section 4).
Electrical Supply 240V~50Hz
Electrical Rating 150W, fused 3A
1.7 Gas Supply
The gas installation shall be in accordance with the rules
in force in the countries of destination.
The supply from the governed meter must be of adequate
size to provide a steady inlet working pressure of
20mbar (8in wg) at the boiler.

Other manuals for Glow-worm swift flow 80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm swift flow 80 and is the answer not in the manual?

Glow-worm swift flow 80 Specifications

General IconGeneral
BrandGlow-worm
Modelswift flow 80
CategoryBoiler
LanguageEnglish

Related product manuals