3.4 Storage of Inverter
3.5 The advantage of the unit
3.3 Size and weight
More detail about the type label as the chart below:
Model
Height (H) Width (W) Depth (D)
Weight
MIN 2500-6000 TL-XH/XE
350mm 13.8inch 375mm 14.8inch 160mm 6.3inch 10.8kg
If you want to storage the inverter in your warehouse, you should choose an appropriate
location to store the inverter.
ØThe unit must be stored in original package , and should be stored in a clean and dry
place, and be protected from dust and water vapor corrosion.
ØThe storage temperature should be always between -25℃and +60℃. And the
storage relative humidity can achieve to 100%.
ØIf there are a batch of inverters need to be stored, the maximum layers for original
carton is four.
ØAfter long term storage, local installer or service department of GROWATT should
perform a comprehensive test before installation.
ØMaximum efficiency of 98.4%
ØWide input voltage range from 80--550Vdc
ØReactive power regulate
ØIntegrated DC switch
ØMulti MPP controller
ØDSP controller
ØTouch control
ØMulti active power control mode
ØEasy installation
ØIntelligent DC arc fault detection(AFCI)
Model Name
MIN 2500 TL-XH/XE MIN 3000 TL-XH/XE MIN 3600 TL-XH/XE
Max input PV voltage
Max input PV current
Start voltage
MPP voltage range
*DC nominal input voltage
*DC input voltage range
*DC Max input/output current
AC nominal voltage
AC grid frequency
Environmental Protection
Rating
Operation Ambient
temperature
500V
500V
550V
12.5A/12.5A
100V
80V~500V
80V~500V 80V~550V
350V~480V
380V
230V
50/60 Hz
2500VA 3000VA 3600VA
11.3A 13.6A 16A
0.8leading…0.8lagging
IP 65
-25...+60℃ (-13...+ 140°F)
with derating above 45°C(113°F)
Max. apparent power
Max ACl output current
Power factor
10A
Model Name
MIN 4200
TL-XH/XE
MIN 4600
TL-XH/XE
MIN 5000
TL-XH/XE
MIN 6000
TL-XH/XE
Max input PV voltage
Max input PV current
Start voltage
MPP voltage range
*DC nominal input voltage
*DC input voltage range
*DC Max input/output current
AC nominal voltage
AC grid frequency
Environmental Protection
Rating
Operation Ambient
temperature
550V
12.5A/12.5A
100V
80V~550V
350V~480V
380V
230V
50/60 Hz
4200VA 4600VA 5000VA 6000VA
19A 20.9A 22.7A 27.2A
0.8leading…0.8lagging
IP 65
-25...+60℃ (-13...+ 140°F)
with derating above 45°C(113°F)
Max. apparent power
Max ACl output current
Power factor
10A
Dimensions and weight
10