116
Item Model 5U105S2SS2FA
Piping
Refrigerant
Type / Charge kg R32 / 2.4
GWP 675
No need to recharge m 40
Recharge g/m 20
Pipe
Liquid mm 5* Φ6.35
Gas mm 3* Φ9.52+2*Φ12.7
Connecting method —— Flared
Drop between IU & OU m ≤7.5
Piping length between IU & OU m ≤10
Total liquid piping length m ≤40
Drop between indoor units m ≤1
Max.Drop between IU &OU m 15
Max.Drop between indoor units m 7.5
Max.Piping length between IU & OU m 25
Max Cable length between IU & OU m 30
Max.Total length m 80
Working temperature
Cooling °C -10~46
Heating °C -15~24
Pto: 47W Psb: 16W Pck: 0W Poff: 0W
Cooling
A (Cap/EER) 9511W/2.8
Heating
A (Cap/COP) 6457W/2.63 Tol (Cap/COP) 7046W/2.56
B (Cap/EER) 7170W/5.12 B (Cap/COP) 4691W/3.74 Tb (Cap/COP) 6457W/2.63
C (Cap/EER) 4095W/9.04 C (Cap/COP) 3108W/5.26 Cd (cooling) 0.25
D (Cap/EER) 4026W/11.98 D (Cap/COP) 2835W/6.52 Cd (heating) 0.25
Max. cooling condition
Indoor temperature:32°C/23°C
Max. heating condition
Indoor temperature:27°C/-°C
Outdoor temperature:46°C/-°C Outdoor temperature:24°C/18°C
kWh/annum 537 kWh/annum-average 2889
kWh/annum-
warm
1279
1. The above performance data are from the combination of 5U105S2SS2FA+2*AS25S2SF2FA+1*AS35S2SF2FA+1*AS50S2SF2FA.
2. Large drop and long piping installation will obviously reduce the total capacity.