-7-
>_]]VbTZR\ <Zb >_^UZdZ_^Vb
——
Cooling Heating
W 6400 7300
W 2100 2000
A 9.3 8.9
W/W
3.04 3.65
W 1500 1800
W 500 500
W
6800 7500
W
2900 2900
——
A / A 12.9 12.9
—— 99% 99%
A
Model / Manufacture ——
Oil charge and type ——
Type ——
Number ——
Type × Number ——
Speed r/min
Motor output/input power W
Air-flows (H/M/L) m³/h
Type / Diameter mm
Face area m²
External mm
Package mm
——
——
W
Noise level H/M/L dB(A)
Weight Net / Shipping kg / kg
Type / Charge kg
No need to recharge m
Recharge g/m
Liquid mm
Gas mm
——
Max.Drop between IU & OU m
Max.Drop between IU & OU m
Max.Drop between indoor units m
Max.Piping length between IU & OU m
Max.Total liquid piping length
m
2. Large drop and long piping installation will obviously reduce the totao capacity.
Between I.D &O.D
5
25
45
1. The above performance data are from the combination of AU222XFERA+AS092XVERA+2*AS122XVERA.
Connecting method
Flared
10(indoor unit lower than outdoor unit)
15 (indoor unit higher than outdoor unit)
55/-/-
54 / 60
Piping
Refrigerant R410A / 2.0
30
20
Pipe 3* Φ6.35
3* Φ9.52
Defrosting method
Automatic by reversible cycle
Crankcase heater power 35
Dimension
(WxDxH)
928/288/680
1015/405/760
Refrigerant control method PMVs
about 3200
Heat exchanger TP2M / 7.0
about 0.52
Outdoor unit
Compressor
TNB175FLBM / MELCO
870CC, MEL 56
Twin Rotary (DC inverter)
1
Fan
Axial × 1
960 / 700 / 500
35/100
Max.Running current (indoor + outdoor)
Power facor(under rating power input)
Fuse size (recommended size)
25
Maximum capacity
Power input (indoor + outdoor)
Power source
1PH, 220-230V~, 50Hz
Power input (indoor + outdoor)
EER / COP
Minimum capacity
Power input
Current input (indoor + outdoor)
Item Model AU222XFERA
Function
Rating capacity