The connection of indoor unit pipes must use double spanners.
The installing torque shall be as given in the following table.
Double-spanner
operation
Pipe expansion dimensions as follows:
Pipe expander
A
Piping Connection
Flare connection
Gas pipe
3-way valve
Indoor
Unit
Outdoor
unit
Liquid
pipe
2-way valve
Flare connection
AD092XLERA
AD122XLERA
AD142XLERA
AD182XLERA
Flare connection
Gas pipe
3-way valve
Indoor
Unit
Outdoor
unit
Liquid
pipe
2-way valve
Flare connection
A
To outdoor unit
To gas pipe
A
(adaptor, from 9.52 to 12.7)
6.35 mm (1/4
"
) 0.8 ~ 1.5
9.52 mm (3/8
"
) 1.0 ~ 1.8
12.7 mm (1/2
"
) 1.2 ~ 2.0
Pipe diameter
? Size A (mm)
Connecting pipe
O.D.(mm)
? 6.35
? 9.52
? 12.70
Installing torque
(N-m)
11.8 (1.2kgf-m)
24.5 (2.5kgf-m)
49.0 (5.0 kgf-m)
Increased installing
torque (N-m)
13.7 (1.4 kgf-m)
29.4 (3.0 kgf-m)
53.9 (5.5 kgf-m)
Slope Damage Bur Partial Overlong
Correct
Incorrect
-
>_]]VbTZR\ <Zb >_^UZdZ_^Vb
70-

Other manuals for Haier AU362XHERA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier AU362XHERA and is the answer not in the manual?

Haier AU362XHERA Specifications

General IconGeneral
BrandHaier
ModelAU362XHERA
CategoryInverter
LanguageEnglish

Related product manuals