EasyManuals Logo
Home>Haier>Air Conditioner>HSU-09HRA103

Haier HSU-09HRA103 User Manual

Haier HSU-09HRA103
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Driverƽ
Torque wrench
ƽ
(17mm,22mm,26mm)
Nipperƽ
Reamerƽ
Hacksawƽ Pipe cutterƽ
Gas leakage detector orƽ
soap-and-water solution
Hole core drillƽ Flaring toolƽ
Spanner(17,19 and 26mm)ƽ Knifeƽ
Measuring tapeƽ
Indoor Unit
Place,robustnotcausingvibration,wherethebodycanbesupportedsufciently.ƽ
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
ƽ
Place, possible to drain easily, where piping can be connected with the outdoor unit.ƽ
Place,wherecoldaircanbespreadin a roomentirely.ƽ
Place, nearby a power receptacle, with enough space around. (Refer to drawings).ƽ
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
ƽ
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent
ƽ
lampsintheroomarelightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.ƽ
Place,possibletobeartheunit,wherevibrationandnoisearenotincreased.ƽ
Place, where discharged wind and noise do not cause a nuisance to the neighbors.ƽ
Place, where a distance markedƽ
is available as illustrated in the above figure.
Before inserting power plug into receptacle, check the voltage without fail.
The power
sourceisthesameasthe
ƽ
corresponding name plate.
Install an exclusive branch circuit of the power.
ƽ
Areceptacleshallbesetupin a distancewherethepowercablecanbe
reached.
Donotextendthecablebycuttingit.
ƽ
Power Source
Preparation
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.
NO.0010519573
Installation Manual of Room Air Conditioner
F
A
C
E
D
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Floor fixing dimensions of the
outdoor unit (Unit:mm)
Fixing of outdoor unit
Fix the unit to concrete or blockƽ
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
ƽ
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
ƽ
house, fix the unit by attaching a
vibration-proof mat.
The marks from to
inthefigurearethe
parts numbers.
Thedistancebetween
the indoor unit and the
floor should be more
than 2m.
ThemodelsadoptHFCfreerefrigerantR410A
more than
10cm
more than 5cm
more than 10cm
more than 10cm
more than
10cm
more than15cm
more than
60cm
A
G
ƽ
ƽ
106.5
106.5
566
31
7
A
F
C
E
D
G
B
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
G
Attention must be paid to
the rising up of drain hose
Selection of Installation Place

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HSU-09HRA103 and is the answer not in the manual?

Haier HSU-09HRA103 Specifications

General IconGeneral
BrandHaier
ModelHSU-09HRA103
CategoryAir Conditioner
LanguageEnglish

Related product manuals