Manifold Gas Pressure
Maximum inlet gas pressure
Minimum inlet gas pressure
10.0”
13.0”
7.0”
240VAC is the factory default
110 - 130VAC, 2A, 50/60Hz
220 - 250VAC, 1A, 50/60Hz
OR
Power Selection
Prior to wiring the UHS make sure the correct
voltage selector plug is inserted into the fused
wiring panel.
Heat Exchanger Flow Requirements
Gas Pressure Testing
To preserve heat exchanger, set ow rates above minimum (accounting
for a dirty lter). Maximum water ow = 125GPM
H150FD
H200FD
20 GPM
Universal H-Series
120VAC/240VAC
240 V
120 V
SPA COM POOL
COM
POOL/
SPA
2-Wire
Remote
3-Wire
Remote
G
240V
FACTORY WIRED
120V
SEE MANUAL
G
L2
N
L1
H250FD
H300FD
25 GPM
H350FD
H400FD
30 GPM
Model Min Min Model Min Model
Power & Remote
Using a Manometer, take a measurement at the inlet
port on the gas valve for both Static Pressure (heater o)
& Load Pressure (heater red); readings should be within
the values on the heater data plate. Then measure the
Manifold Pressure from the outlet port on the gas valve.