112
PIR Alarm
Purpose:
A PIR (Passive Infrared) alarm is triggered when an intruder moves within the
detector's field of view. The heat energy dissipated by a person, or any other warm
blooded creature such as dogs, cats, etc., can be detected.
Steps:
1. Enter the PIR Alarm Settings interface:
Configuration > Advanced Configuration> Basic Event> PIR Alarm
Figure 10-13 Setting PIR Alarm
2. Check the checkbox of Enable to activate the PIR alarm function.
3. Input the alarm name in the text field as desired.
4. Check the checkbox to select the linkage methods taken for the PIR alarm.
5. Click the Edit button to set the arming schedule.
6. Click Save to save the settings.
7. Go to Configuration > Advanced Configuration> System> Remote Control to
arm the camera.