If nails are driven too shallow, turn the adjuster to
the deep side.
3 Stop turning the adjuster when a suitable
position is reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
USING THE BLOW NOZZLE
WARNING
Be sure to release your finger from the trigger before using the
blow nozzle.
Do not point the air outlet at a person.
Do not use the blow nozzle with the push lever left fit.
This Nailer has a blow nozzle that blows out wood
shavings which occur during work.
Press the knob with your thumb to use the blow nozzle,
as shown in the figure.
NOTE:
When the blow nozzle is used for a long time, the
nailing force may degrade temporarily. In this case,
allows the air supply pressure to stabilize before
starting work.
Oil in the body or drained water from the compressor
can sometimes spout out of the air outlet. It is
recommended that you once conduct a test before
use and see if such phenomenon happens at an
environment where spouted oil will cause any
inconvenience.
Too Deep
Too Shallow
Turn Adjuster
Turn Adjuster
Flush
Flush
2
2
Knob
air outlet

Table of Contents

Other manuals for Hitachi NT 65M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi NT 65M and is the answer not in the manual?

Hitachi NT 65M Specifications

General IconGeneral
BrandHitachi
ModelNT 65M
CategoryNail Gun
LanguageEnglish

Related product manuals