Do you have a question about the Honeywell Centra Line EAGLE and is the answer not in the manual?
Brand | Honeywell |
---|---|
Model | Centra Line EAGLE |
Category | Controller |
Language | English |
General safety rules and precautions for installation and operation.
Details on compliance with EN 60730 standards for controllers.
Guidelines for the disposal of waste electrical and electronic equipment.
Information on regulatory standards and product approvals.
Electrical power, consumption, temperature, and humidity requirements.
Controller dimensions, degree of protection, and fire class.
Details on the different available EAGLE controller models.
Visual representation of the CentraLine BACnet System architecture.
Critical safety precautions before making electrical connections.
Details on Host and Device USB ports for connectivity.
Ethernet port functionality, LEDs, and LonWorks connection via IF-LON.
Overview of the two RS485 interfaces on the EAGLE Controller.
Configuration of RS485-1 bias and termination resistors via slide switch.
Details on fixed bias and termination resistors for RS485-2.
Adherence to EIA-RS485 standards for communication.
Relationship between baud rate and maximum cable length for RS485.
Pre-installation requirements and safety notes for mounting.
Physical size and mounting details of the EAGLE Controller.
Safety precautions for electrical wiring and connections.
Fusing recommendations and push-in terminal usage guidelines.
Guidelines for powering the EAGLE Controller.
Detailed terminal functions for each EAGLE controller model.
Data for 1450 series transformers and CRT series AC/DC converters.
Methods for powering field devices and Panel Bus I/O modules.
Information on directly wiring the RIN-APU24 to the EAGLE Controller.
Example connection diagram for the CLEA2026Bxx controller.
Notes on fusing specifications and signal cable routing.
Details on optional XS830/XS831 Auxiliary Terminal Packages.
Configuration and specifications of universal input channels.
Configuration and specifications of analog output channels.
Specifications for binary input channels and pulse counter function.
Polarity and state detection for binary inputs.
Using binary inputs as pulse counters and frequency limits.
Specifications for the controller's binary output relay contacts.
Initial access methods via USB or Ethernet for setup.
Details and order numbers for optional accessories.
Overview of available CentraLine Panel Bus I/O module types.
Bus length, topology, and module limits for Panel Bus connections.
Wiring example for RS485-1 connection with a single transformer.
Wiring example for RS485-1 connection with two transformers.
Wiring example for RS485-2 connection with a single transformer.
Wiring example for RS485-2 connection with two transformers.
Cable specifications for Panel Bus I/O module power and communication.
Cable specifications for powering and communicating with field devices.
Recommendations for routing and shielding communication cables.
Bus length, isolation, and device limits for BACnet MS/TP.
Wiring diagram for connecting RS485-1 to BACnet MS/TP buses.
Wiring diagram for connecting RS485-2 to BACnet MS/TP buses.
Diagnosing controller issues using power, status, Tx, and Rx LEDs.
Guidance for troubleshooting Panel Bus I/O modules.
SELV compliance and grounding recommendations for EAGLE systems.
Determining when the EN60204-1 standard is applicable to EAGLE systems.
Electrical safety requirements defined by EN60204-1.
Wiring example for grounding EAGLE with a single transformer.
Wiring example for grounding EAGLE with mixed controllers.
Typical accuracies of internal NTC20kΩ sensor inputs.
Thresholds for recognizing sensor failures (short-circuit, break).
Relationship between sensor resistance and temperature.
Data table for NTC 20 kΩ sensors across various temperatures.