DOC-02-159:rev C - Page 4 of 8
PRODUCT LINE INFORMATION
Main System Components
CPU2-3030AU: AFP-3030 central processing unit including field
interfaces.
DISP-3030AU: Keypad and display; includes 640-character backlit
LCD display, QWERTY programming and control keypad.
NPS-5CHS/NPS-11CHS:24VDC power supply unit for AFP-3030
ELCM-320: Loop Control Module. Provides one SLC. AFP-3030
supports up to five LCM-320s and five LEM-320 expanders for a total
of ten SLCs.
LEM-320:Loop Expander Module. Expands an ELCM-320.
Networking Options
NCA-2: Network Control Annunciator, 640 characters. An alternate
primary display for CPU2-3030AU can be provided by the NCA-2, or
ONYXWorks. On network systems, the NCA-2 connects to a standard
NCM or HS-NCM. See DOC-02-166.
AFP-2800:Addressable fire alarm control panel. DOC-02-023
NCM-W, NCM-F: Standard Network Communications Modules. Wire
and multi-mode fiber versions available. See DOC-02-109.
HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network
Communications Modules that can connect to two nodes. Wire,
single-mode fiber, multi-mode fiber, and media conversion models are
available. See DOC-02-072.
RPT-W,RPT-F, RPT-WF: Standard-network repeater board with wire
connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a
change in media type between wire and fiber (RPT-WF). Not used with
high-speed networks. See DOC-02-165.
ONYXWorks:Graphics PC workstation, ONYXWorks GUI software, and
computer hardware. See DOC-02-080.
NFN-GW-EM-3:NFN Gateway, embedded. See DOC-02-091.
NWS-3:NOTI•FIRE•NET™ Web Server. See DOC-02-079.
VESDA-HLI-GW: VESDAnet high-level interface gateway. See DOC-02-
142.
BACNET-GW-3:Bacnet Gateway, embedded. See DOC-02-082.
MODBUS-GW-3:Modbus Gateway, embedded. See DOC-02-097.
Auxiliary Power Supplies and Batteries
NPS-5S: One optional for each AFP-3030. Power supply and battery
charger with two 24 VDC outputs up to 5A output total. Charges 7 to
200 AH batteries. Auxilary power for panel or panel equipment.
NPS-11S: One optional for each AFP-3030. Power supply and battery
charger with two 24 VDC outputs up to 11A output total. Charges 7 to
200 AH batteries. Auxilary power for panel or panel equipment.
BATTSeries:Batteries. PS5/PS11 and NPS-5S/NPS-11S use two 12
volt, 7 to 200 AH batteries. See DOC-02-171.
Audio Options
DVC-EM: Digital Voice Command, digital audio processor with message
storage for up to 32 minutes of standard quality (4 minutes at high
quality) digital audio. See DOC-02-130.
DVC-KD:DVC-EM keypad for local annunciation and controls;
status LEDs and 24 user-programmable buttons. See DOC-02-130
DS-FM,DS-SFM:Fiber conversion modules for DVC-EM, and DAA2
Series amplifiers. See DOC-02-130/DOC-02-131
DAA2-5070(E):50W, 70.7 Vrms Digital Audio Amplifier
assembly with power supply; includes chassis. See DOC-02-131.
CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2
chassis assembly. See DOC-02-130.
DA-30/DA-60/DA-120: Digital Amplifier. DA-30 is 30 watts, DA-60 is
60 watts, DA-120 is 120 watts, 100 Vrms. Includes audio input and
amplified output supervision. See DOC-02-066
DA-DISP/A, DA-DISP/B, DA-DISP/C, DA-DISP/D, DA-DISP/E:
Display control and paging microphone modules for DA series amplifiers.
See DOC-02-066.
SDM-4: 4 way Speaker distribution module for use with DA series
amplifiers. See DOC-02-085
Compatible Devices, EIA-485 Ports
ACM-24AT: ONYX® Series ACS annunciator – up to 96 points of
annunciation with Alarm or Active LED, Trouble LED, and switch per
circuit. Active/Alarm LEDs can be programmed (by powered-up switch
selection) by point to be red, green, or yellow; the Trouble LED is always
yellow. See DOC-02-167.
AEM-24AT:Same LED and switch capabilities as ACM-24AT; expands
the ACM-24AT to 48, 72, or 96 points. See DOC-02-167.
ACM-48A: ONYX® Series ACS annunciator – up to 96 points of
annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs
can be programmed (by powered-up switch selection) in groups of 24
to be red, green, or yellow. Expandable to 96 points with one AEM-48A.
See DOC-02-167.
AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A
to 96 points. See DOC-02-167.
ACM-8RA: Relay Module with eight Form-C contacts. See DOC-02-
168.
LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display.
Mounts up to 1800m from panel. Up to 32 per FACP. See DOC-02-169.
SCSSeries(SCS-8A,SCE-8A,SCS-8L): Smoke control station; eight
(expandable to 16) circuits. See DOC-02-035.
LDM-32: Lamp Driver Module - up to 32 points that provide low-current
outputs to LEDs, typically used for graphical mimics. See DOC-02-035.
LDM-E32: Same LED output capabilities as LDM-32; expands outputs
up to 64 points. See DOC-02-035.
LDM-R32: Relay module for LDM-32, LDM-E32 - up to 32 points that
provide 1A relay outputs. See DOC-02-035.
Compatible Intelligent Devices
FSB-200:Intelligent beam smoke detector. See DOC-02-051.
FSB-200S:Intelligent beam smoke detector with integral sensitivity test.
DOC-02-051.
FSC-851:FlashScan IntelliQuad Advanced Multi-Criteria Detector. See
DOC-02-048.
FSI-851AUS: Low-profile FlashScan ionization detector. See DOC-02-
025.
FSP-851AUS: Low-profile FlashScan photoelectric detector. See DOC-
02-026.
FST-851AUS: FlashScan thermal detector 57°C. See DOC-02-027.
FST-851RAUS:FlashScan thermal detector 57°C with rate-of-rise. See
DOC-02-027.
FST-851-WP: FlashScan sealed thermal detector 57°C. See DOC-02-
135.
FST-851R-WP: FlashScan sealed thermal detector 57°C with rate-of-
rise. See DOC-02-135.
FST-851HAUS: FlashScan 88°C high-temperature thermal detector.
See DOC-02-027.
FAPT-851AUS: FlashScan Acclimate Plus™ low-prole multi-sensor
detector. See DOC-02-029.
FSL-751:FlashScan VIEW® laser photo detector. See DOC-02-049.
SDX-851AUS: Low-profile CLIP photoelectric detector. See DOC-02-
128.
FDX-851AUS: FlashScan thermal detector 57°C. See DOC-02-133.
FDX-851RAUS:FlashScan thermal detector 57°C with rate-of-rise. See
DOC-02-0133.
IDX-751AE:Intrinsically-safe CLIP photoelectric detector. See DOC-02-
129