Page #58 background imageLoading...
Page #58 background image
44 PX940 User Guide
Verifier Settings
This section gives a brief description of the verifier settings.
Verification Type
Select the verification type to check the barcode.
None - No barcode validation
Read/No Read - Validate if barcode is readable
ISO15415/15416 - Full ANSI grading of barcode
Passing Grade
Sets the minimum passing grade for barcode grading. Grade 0.0 (F) is the lowest
grade. Grade 1.5 (C) is the default and recommended by ISO standard. Only
applied when verification type is set to ISO15415/15416.
Aperture
Indicates the aperture size in mils (1000 mils = 25.4mm) used for verification.
Aperture size will be chosen automatically based on ISO standard. Change only if
required by an overriding application.
Maximum Consecutive Failures
Sets maximum number of times printer encountered verification failure consecu-
tively before prompting for user action. This setting is only applicable when the
Verification Failure Action is set to Void and Reprint.
Verification Failure Action
Indicates action to take when label fails verification.
Void and Reprint (default) - Retract and void the failed label, then reprint the
failed label. Stop reprint if the maximum consecutive failures have been
reached.
Ignore and Continue - No voiding when verification fails. Result is saved and
next label is printed.
Note: Note: During multiple label printing, printer will void the failed label (plus all printed
and yet to be verified labels) in order to keep the good labels in sequence.
Save Failed Label Images
When enabled, the printer saves all failed label images in non-volatile memory.
Maximum 100 images can be saved (if memory available). At maximum capacity
oldest image file will be replaced by newest.

Table of Contents

Other manuals for Honeywell PX940

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell PX940 and is the answer not in the manual?

Honeywell PX940 Specifications

General IconGeneral
Ethernet LANYes
USB 2.0 ports quantity2
Connectivity technologyWired & Wireless
Flash memory256 MB
Internal memory1024 MB
Page description languagesDP, DPL, XML, ZPL II, IPL
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)20 - 85 %
Cables includedAC
ColorNo
Print technologyDirect thermal / Thermal transfer
Maximum resolution203 x 203 DPI
Minimum print length4800 mm
Maximum printing width108 mm
Ribbon width110 mm
Core diameter25 mm
Ribbon length450 m
Maximum roll diameter80 mm
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
DisplayLCD
Product colorBlack
Display diagonal3.5 \
Harmonized System (HS) code84433210
Weight and Dimensions IconWeight and Dimensions
Depth506 mm
Width261 mm
Height398.7 mm
Weight23000 g