EasyManuals Logo

Honeywell SUPER TRADELINE S8610U User Manual

Honeywell SUPER TRADELINE S8610U
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION INSTRUCTIONS
69-1955
®
A
u
t
oma
ti
c
I
gn
iti
on
S
ys
t
ems
ANSI Z21.20
S8610U Universal Intermittent Pilot Gas
Ignition Control
SUPER TRADELINE
®
APPLICATION
The SUPER TRADELINE
®
S8610U Universal
Intermittent Pilot Gas Ignition Control Module is designed
to provide easy field replacement of a wide range of
intermittent pilot ignition modules manufactured by
Honeywell, Robertshaw, Johnson Controls, and others.
The S8610U control provides ignition sequence, flame
monitoring, and safety shutoff for intermittent pilot central
furnaces, residential boilers, and other heating
appliances. The S8610U replaces existing flame
rectification type, intermittent pilot ignition modules with
the following characteristics:
Single rod (local sense) or two rod (remote sense)
flame sensing
Non-100 percent shutoff, 100 percent shutoff/lockout,
or 100 percent shutoff/continuous retry
Natural or LP gas
Shutoff/lockout times of 15 seconds or longer
Prepurge configurable to 30 seconds or no prepurge
Pilot burners with flow rates of 1,500 Btuh or less
With or without integral damper connector
Table 1 describes the key features of the S8610U
control.
WARNING
Check Table 2 on page 2 before replacing an
existing intermittent pilot control with the S8610U.
If the existing control is not listed, do not use the
S8610U to replace it unless you are certain the
specifications match those of the existing control.
A complete list of the specific Honeywell and other
modules that the SUPER TRADELINE
®
S8610U is
designed to replace is provided in Table 2 on page 2.
The SUPER TRADELINE
®
S8610U package contains
complete, easy-to-use instructions, plus the accessories
required to adapt the existing spark cable (Rajah, stud,
nail, or other) to the spark terminal on the control module.
It also help assure proper marking of the wires attached
to the existing control and a label with LED code
information that can be affixed in the appliance.
IMPORTANT
The S8610U control module is not designed to
replace controls with:
Flame sensing other than by flame rectification
(White Rodgers Cycle-Pilot
®
, or Robertshaw
thermal sensing)
Standing pilot appliances
Direct main burner ignition
The S8610U provides:
Natural or LP gas
Pilot burner ignition using an internally generated high
voltage spark
Flame rectification circuit to monitor flame presence
Monitoring of 24 Vac, pilot, and main gas valve
Two LED indicators for flame presence/strength and
system status/errors
EnviraCOM™ communication protocol for system
diagnostics
Vent Damper connection
The S8610U is designed for a wide variety of natural or
liquid propane fueled applications.
Table 1. S8610U Universal Intermittent Pilot Gas Ignition Control.
Igniter-Sensor
Type
Valve Current
Rating
@ 24 Vac
Prepurge
Timing
Trial for
Pilot
Ignition
Ignition
Sequence
Type
Ignition Sequence
(After prepurge, if prepurge is
selected)
Integral
Damper
Connector
Separate
(two rod; remote
flame sensing)
or
Combination
(one rod; local
flame sensing)
1.0 A Pilot
and
2.0 A Main
None or 30
seconds
(field
selectable)
15 or 90
seconds
(field
selectable)
Retry Spark and pilot gas ON until lightoff or trial
for ignition ends.
If established flame is lost, trial for
ignition restarts immediately.
If pilot fails to light, pilot gas and spark
Off (100% shutoff). After 5 minute delay,
a new trial for ignition is initiated. This
sequence continues until lightoff or “Call
for Heat” is removed.
Included for use as
needed.
If initially installed
and powered up
with damper
attached, unit
must always have
a vent damper
connected.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SUPER TRADELINE S8610U and is the answer not in the manual?

Honeywell SUPER TRADELINE S8610U Specifications

General IconGeneral
ModelS8610U
CategoryController
Ignition TypeIntermittent Pilot
Operating Voltage24V AC
Frequency60 Hz
Ignition Trials To Lockout1
Ignition SourceSpark
Approvals, Underwriters Laboratories Inc.UL Listed
Approvals, Canadian Standards AssociationCSA Certified
Input Voltage24V AC
Temperature Range-40°F to 175°F (-40°C to 79°C)
Operating Temperature-40°F to 175°F (-40°C to 79°C)
Pilot Gas Valve TypeSingle Stage

Related product manuals