EasyManuals Logo

HP ProLiant Gen9 User Manual

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #229 background imageLoading...
Page #229 background image
HP Virtual Connect errors 229
Description: A profile was changed or assigned and some configuration required that the server be powered
off to make the change. For example, if the number of Ethernet connections is changed for a profile that is
assigned to a server with Flex-10 NICs, then the server must be powered off.
Possible causes:
• A user action results in a profile that requires the server be powered off to make the change or initially
assign or remove the profile.
• VCM restarts and detects a powered on server that has a profile assigned to the bay and the profile
needs to make a change on the server that requires it to be powered off.
Action: Power down the server and retry the change.
Ethernet Network events (7000-7999)
7012 - Enet Network state FAILED
Severity: CRITICAL
Description: The VC Enet Network lost all uplink connectivity because of lack of configured ports or all
configured ports are in a bad state or because a bad or incompatible transceiver was inserted.
Possible causes:
• All of the uplink ports associated with the network are unlinked.
• The user disables all the uplink ports associated with a non-shared network.
• The user disables all the uplink ports in a shared uplink set associated with a shared network.
Action:
• Connect the uplink ports.
• Enable the uplink ports associated with a non-shared network.
• Enable the uplink ports in a shared uplink set associated with a shared network.
7014 - Enet Network state DISABLED
Severity: MAJOR
Description: A network has been administratively disabled.
Possible cause: A user disabled a network through the UI.
Action: Enable the network through the UI.
FC Fabric events (8000-8999)
8012 - FC Fabric state FAILED
Severity: CRITICAL
Description: The VC fabric lost all uplink connectivity because of lack of configured ports or all configured
ports are in a bad state.
Possible causes:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals