Microsoft Windows Event ID and SNMP traps 291
• cpqSsBoxTempStatus
Supporting SNMP Trap Description: “Storage System temperature ok.”
Event identifier: cpqstmsg.dll - 1098 (Hex)0x4435044a (Service Event)
Log Severity: Information (1)
Log Message: Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4, port %5,
bay %6 with serial number “%7”, does not have drive threshold monitoring enabled.
Event Identifiers 1101-1199
NT Event ID: 1101 (Hex)0x8435044d (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Side Panel Removed.
Log Message: The side panel has been removed on the %6 %7 storage system connected to SCSI bus %5 of
the controller in slot %4.
SNMP Trap: cpqSs3SidePanelRemoved - 8013 in CPQSTSYS.MIB
Symptom: Storage System side panel is removed. The side panel status has been set to removed. The storage
system's side panel is not in a properly installed state. This situation may result in improper cooling of the
drives in the storage system due to air flow changes caused by the missing side panel.
User Action: Replace the storage system side panel.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsBoxSidePanelStatus
Supporting SNMP Trap Description: “Side panel is removed from unit.”
NT Event ID: 1102 (Hex)0x4435044e (cpqstmsg.dll)
Log Severity: Information (1)
Event Title: Storage System Side Panel In Place.
Log Message: The side panel has been replaced on the %6 %7 storage system connected to SCSI bus %5 of
the controller in slot %4.
SNMP Trap: cpqSs3SidePanelInPlace - 8012 in CPQSTSYS.MIB
Symptom: Storage System side panel is in place. The side panel status has been set to in place. The storage
system's side panel has returned to a properly installed state.
User Action: None.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsBoxSidePanelStatus
Supporting SNMP Trap Description: “Side panel is re-installed on unit.”

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals