EasyManuals Logo

HP ProLiant ML30 Gen10 Plus User Manual

HP ProLiant ML30 Gen10 Plus
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
Server warnings and cautionsServer warnings and cautions
WARNING:WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment, disconnect
the power cord to remove power from the server. Pressing the Power On/Standby button does
not shut off system power completely. Portions of the power supply and some internal circuitry
remain active until AC power is removed.
WARNING: WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
WARNING:WARNING:
To reduce the risk of fire or burns after removing the energy pack:
Do not disassemble, crush, or puncture the energy pack.
Do not short external contacts.
Do not dispose of the energy pack in fire or water.
Do not expose the energy pack to low air pressure as it might lead to explosion or leakage of
flammable liquid or gas.
Do not expose the energy pack to temperatures higher than 60°C (140°F).
After power is disconnected, battery voltage might still be present for 1s to 160s.
CAUTION:CAUTION:
Protect the server from power fluctuations and temporary interruptions with a regulating UPS. This device protects the
hardware from damage caused by power surges and voltage spikes and keeps the server in operation during a power
failure.
CAUTION:CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or
replacement procedure. Improper grounding can cause electrostatic discharge.
CAUTION:CAUTION:
To avoid data loss, Hewlett Packard Enterprise recommends that you back up all server data before installing or
removing a hardware option, or performing a server maintenance or troubleshooting procedure.
CAUTION: CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in
this manner results in improper airflow and improper cooling that can lead to thermal damage.
Server warnings and cautions 67

Table of Contents

Other manuals for HP ProLiant ML30 Gen10 Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML30 Gen10 Plus and is the answer not in the manual?

HP ProLiant ML30 Gen10 Plus Specifications

General IconGeneral
Processor Sockets1
MemoryUp to 128 GB DDR4 ECC UDIMM
Memory Slots4
Form FactorTower
ProcessorIntel Xeon E-2300 series
StorageUp to 4 LFF or 8 SFF drives
RAID SupportHPE Smart Array S100i, S100i SR Gen10 SW RAID
Network1 x 1GbE
Power Supply350W
ChipsetIntel C252
Storage ControllerHPE Smart Array S100i, S100i SR Gen10 SW RAID
Maximum Internal StorageUp to 64 TB
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi
WeightApprox. 10.5 kg

Related product manuals