M3858 • 1/21/21 • © 2021 Hunter Fan Company
CEILING FAN REMOTE WALL CONTROL
Model 99771
6
9
7
Installing the battery
Installing the Wall Plate
Wiring the Wall Control
Installation
Troubleshooting
Remote Function Guide
Before installation, use the pull chains to set the fan speed
to HIGH and the light to ON. Ensure the power is OFF at the
outlet box and wall switch location before proceeding with
installation.
Turn Power
OFF
2
3
1
4
Remove the canopy. If uncertain how to remove it, reference the
fan’s owner’s manual. With wiring exposed, it may be helpful
to note existing wire connections or take a digital photo for
reference. Remove the wire connectors that connect the wires
from the outlet box to the fan, leaving the grounding wires
connected.
Turning off the power
Wiring the receiver to the fan
Installing the receiver
Removing the canopy
Choose the hanging system that most closely resembles
the one used by your fan, and install the receiver and wire
as directed.
You may have installation issues if the fan is installed on an
angled ceiling. For assistance, call 1-888-830-1326.
OR OR OR
Note: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire,
leaving a minimum of 8” remaining. Re-strip the fan lead wires 1/2”. Place remaining excess wire into the ceiling
electrical box. The bracket and fan must remain properly grounded.
Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the
wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of
the outlet box.
Note: If you are uncertain about wire colors or connections, please contact a qualied electrician.
Ceiling
Bracket
A
Fan Body
Cable Tie
To access the battery
compartment, slide the
battery door up.
Replace the used battery
with two AAA batteries when
needed.
Install the shorter screws through the wall
control plate and into the screw holes in the
wall control.
Battery
Door
Using the orange wire connectors,
connect the blue wire from the receiver
to the blue wire (or possibly black with
white stripe wire) from the fan. Connect
the yellow wire from the receiver to the
black wire from the fan.
F
R
O
M
R
E
C
E
I
V
E
R
black
blue
yellow
blue
F
R
O
M
F
A
N
5
Using the orange wire connectors, connect the black wire
(ungrounded) from the ceiling to the black wire from the
receiver. Connect the white wire (grounded) from the ceiling
to both the white wire from the receiver and the white wire
from the fan.
AFTER ALL WIRES ARE CONNECTED and secured with wire
connectors, re-install the canopy.
Use the pull-chain switch on the fan to set the fan speed to
the HIGH position before operation.
Wiring the receiver and fan to the ceiling
Turning on the power
Reference the included remote function card for
information on how to use your wall control!
F
R
O
M
C
E
I
L
I
N
G
black
white white (grounded)
black (ungrounded)
F
R
O
M
R
E
C
E
I
V
E
R
F
R
O
M
F
A
N
white
If you are installing multiple remote-controlled fans
on the same circuit breaker,
you may need to perform a few extra steps to prevent interference or faulty operation of
your remote controls.
Go to www.HunterFan.com/FAQs and click “How do I properly install multiple remote-
controlled fans?” for more information.
ON
Turn Power
IMPORTANT
10
11
8
Installing the Wall Control
Install the longer screws through the slots
in the wall control into the switch box screw
holes.
8
Installing the Wall Control
Install the longer screws through the slots in
the wall control into the switch box screw holes.
1. Connect the grounding wire from the
wall control to the ground control from
the switch box using the provided wire
nuts.
2. Connect the “LIVE IN” from the switch
box to the “~VAC” from the wall control
using the provided wire nuts.
3. Connect the “LIVE OUT” from the switch
box to the “FAN” out from the wall control
using the provided wire nuts.
4. Push all wires into the switch box.
Fan On/Off
Light Dimming
Control
Dimming Mode
On/Off
+
Light On/Off
Light High
Fan High
Light Low
Fan Low
Power On/Off
Long
Press
Long
Press
Long
Press
Long
Press
Long
Press
Fan Speed
Control
Key Press Function
+
Long
Press
The remote transmitter is already paired to the receiver and ready to use. If your need to pair
your remote, cycle power to the fan by turning power off and back on at the wall switch (or
circuit breaker if necessary). Within three minutes, do the following:
All wiring must be in accordance with national
and local electrical codes ANSI/NFPA 70. If you
are unfamiliar with wiring or in doubt, consult a
qualied electrician.
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet box
associated with the wall switch location.
This product contains alkaline batteries:
• Do not mix new and old batteries.
• Do not mix alkaline, carbon-zinc or
rechargeable batteries.
• Dispose of all old batteries in
accordance with applicable laws and
regulations.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
This device complies with RSS-210 of Industry Canada. Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause
undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: Reorient or relocate the
receiving antenna, Increase the separation between the equipment and receiver,
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. Consult the dealer or an experienced radio/TV technician
for help. Note: Any changes or modifications to the transmitter or receiver not
expressly approved by Hunter Fan Company may void one’s authority to operate
this remote control. Chemical burn hazard. Keep batteries away from children.
This remote contains a lithium button cell battery. If a new or used lithium button/
coin cell battery is swallowed or enters the body, it can cause severe internal burns
and can lead to death in as little as 2 hours. Always completely secure the battery
compartment. If the battery compartment does not close securely, stop using the
product, remove the batteries, and keep it away from children. If you think batteries
might have been swallowed or placed inside any part of the body, seek immediate
medical attention. Dispose of cells properly and keep away from children. Even
used cells may cause injury.
This product conforms to UL Standard 1917.
WARNINGS
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser
of the Control (“Control”): Your Control is warranted to be free from defects in material and
workmanship for a period of one year from the date of sale. If the Control malfunctions or fails
within the warranty period due to a defect in material or workmanship we will replace it free
of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY
AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY
IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY,
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE
PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL. This warranty
excludes malfunctions or failures which were caused by repairs by persons not authorized by
us, mishandling, improper installation, modications, or damage to the Control while in your
possession, or unreasonable use. This warranty does not apply to batteries or to deterioration
or damage to the product caused by the use of faulty batteries. To obtain a replacement, return
your Control postage prepaid along with proof of purchase to Hunter Fan Company Service
Department at 7130 Goodlett Farms Pkwy., Memphis, TN 38016. IN NO EVENT SHALL HUNTER
FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO
NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION
OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS
OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Read and Save These Instructions