1. Press and hold the Programs button, and at the same time press in the
recessed Reset button with the tip of a ball point pen.
2. Release the Reset button and continue holding the Programs button until
the Reset Memory screen appears (then release the Programs button).
The display will show the following Reset options:
Programs: Erases Day schedules, start times, and run times.
Flow Totals: Clears the running flow total histories (they will restart with 0.0
for all entries), only.
Logs: Clears all Station alarm logs and Controller alarm logs.
Names: Clears all user programmed names, including Programs, Stations
and SSG's.
All Data: Clears all of the above items, and controller returns to original out-
of-the-box programming state.
Use the up and down arrows to highlight the desired type of Reset. Press the +
button to select it.
A confirmation message will appear. If + is pressed again, the selection will be reset.
Note: None of the reset functions will erase the Easy Retrieve "backup", if one
has been made.