Electrical hazards (especially primary power)
Primary voltage on the frame can cause serious or lethal electrical shock.
Explosive hazards
A damaged CRT face or a bulging capacitor can cause serious injury.
Mechanical hazards
Loose or missing items (for example, nuts and screws) can cause serious injury.
To inspect each node for unsafe conditions, use the following steps. If necessary, see any suitable safety
publications.
Procedure
1. Turn off the system and disconnect the power cord.
2. Check the frame for damage (loose, broken, or sharp edges).
3. Check the power cables by using the following steps:
a) Ensure that the third-wire ground connector is in good condition. Use a meter to check that the
third-wire ground continuity is 0.1 ohm or less between the external ground pin and the frame
ground.
b) Ensure that the power cord is the appropriate type, as specied in the parts listings.
c) Ensure that the insulation is not worn or damaged.
4. Check for any obvious nonstandard changes, both inside and outside the unit. Use good judgment
about the safety of any such changes.
5. Check inside the node for any obvious unsafe conditions, such as metal particles, contamination,
water or other fluids, or marks of overheating, re, or smoke damage.
6. Check for worn, damaged, or pinched cables.
7. Ensure that the voltage that is specied on the product-information label matches the specied
voltage of the electrical power outlet. If necessary, verify the voltage.
8. Inspect the power-supply assemblies and check that the fasteners (screws or rivets) in the cover of
the power-supply unit are not removed or disturbed.
9. Check the grounding of the network switch before you connect the system to the storage area network
(SAN).
Checking external devices
Ensure that you complete an external device check before you install or service the system.
Procedure
To conduct an external device check, complete the following steps.
1. Verify that all external covers are present and are not damaged.
2. Ensure that all latches and hinges are in the correct operating condition.
3. Check the power cords for damage.
4. Check the external signal cables for damage.
5. Check the cover for sharp edges, damage, or alterations that expose the internal parts of the device.
6. Correct any problems that you nd.
Checking internal devices
Ensure that you complete an internal device check before you install or service your system.
About this task
To conduct the internal device check, use the following steps.
xiv
SAN Volume Controller 8.3.1: Machine Types 2145, 2147 Models SA2, SV2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller 2145 and is the answer not in the manual?

IBM SAN Volume Controller 2145 Specifications

General IconGeneral
BrandIBM
ModelSAN Volume Controller 2145
CategoryServer
LanguageEnglish

Related product manuals