Mini
Mini C24 G.C. appliance No. 47---348---18
Mini C28 G.C. appliance No. 47---348---19
Mini C32 G.C. appliance No. 47---348---25A
Mini S24 G.C. appliance No. 41---392---98
Mini S28 G.C. appliance No. 41---392---99
Destination countries: GB, IE
INTRODUCTION
Mini are wall mounted, room sealed, non condensing boilers
featuring full s equence automatic spark ignition and fan
assisted combustion.
Mini C24, Mini C28 and Mini C32 are low water content
combination gas boilers.
Mini S24 and Mini S28 are low water content system gas
boilers.
SAFETY
Current Gas Safety (Installation & Use)
Regulationsorrulesinforce
In your own interest, and that of safety, it is the law that this boiler
must be installed by CORGI registered installer or in IE a
competent person, in accordance with the above regulations.
It is essential that the inst ructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
ELECTRICITY SUPPLY
Theappliancemustbeefficientlyearthed.
Supply 230 V 50 Hz. The fusing should be 3.15 A.
Connection must be made in a way that allows complete
isolation of the electrical supply, such as a double pole switch,
having a 3 mm (1/8”) contact separation in bot h poles, or a
plug and socket serving only the boiler and system controls.
The means of isolation must be accessibl e to the user after
installation.
IMPORT ANT NOTES
F This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
F If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
F Under no circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
F If it is known or suspected that a fault exist on the boiler
then it MUST NOT BE USED until the fault has been
corrected by a CORGI registered installer or in IE a
competent person.
F This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
conc erning use of the appliance by a person responsible
for their safety.
F Children should be supervised to ensure that they do not
play with the appliance.
MINIMUM CLEARANCES
Clearances of 254 mm (10”) above and below, 25 mm (1“)
at left, 50 mm (2“) at right and 450 mm (17 3/4“) at the front of
theboilercasemustbeallowedforservicing.
After installation the following clearances are allowable during
use, providing the encasing parts are removeable for servicing:
The bottom clearance can be reduced to 20mm (3/4”).
The front clearance can be reduced to 50mm (2”).
BOILER CONTROLS
BC D E F GA
Mini C
Mini S
A Appliance operation lamps
B Domestic hot water temperature control
Mini C24,Mini C28,Mini C32.
BServiceknobMini S24,Mini S28.
C Main switch and radiator temperature control
D Boiler reset button
E Lock ---out signal lamp
F Programmer (optional) for Mini C24, Mini C28, Mini C32
boilers only.
G System pressure and temperature gauge
TO LIGHT THE BOILER
1 Check that the valves located in the lower part of the boiler
are open.
2 Switch the electricity supply on. The appliance operation
lamps A will flash every 4 seconds (stand---by condition).
For combination models Mini C24, Mini C28 and Mini C32
3 If the boiler is to be used for CH and DHW position the
main switch as in the following illustration. The appliance
On lamp A will flash every 2 seconds (operating boiler).
C
A
ForsystemmodelsMiniS24andMiniS28
4 To operate the boiler position the main switch as in the
following illustration. The appliance operation lamps A will
flash every 2 seconds (operating boiler).
C
A
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE
Ideal Stelrad Group is a member of the Benchmark initiative and fully supports the aims
of the programme. Benchmark has been introduced to improve the standards of instal-
lation and commissioning of central heating systems in the UK and to encourage the
regular servicing of all central heating systems to ensure safety and efficiency .
All CORGI registered installers carry a CORGI ID card, and have a reg istration number. Both should be recorded in the Benchmark
Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300.