ENGLISH 16
Adjustingminimumgassettingoftaps
To ensure that the minimum setting is
correctly adjusted, remove the knob (E) and
proceed as follows:
- tighten screw to reduce the ame height
(-);
- loosen screw to increase the ame
height (+).
The adjustment must be performed with the
tap in minimum gas setting position (small
ame ) .
- The primary air of the burners does not
need to be adjusted.
- At this stage, light up the burners and
turn the knobs from max position
to minimum position
to check ame
stability.
Upon completion of adjustment, reseal
the work surface using sealing wax or an
equivalent material.
GasSafetyRegulations
The law requires that all gas appliances
are installed by competent persons in
accordance with the current gas safety
regulations. Failure to install appliances
correctly may lead to prosecution.It is in
your own interest, and that of safety, to
ensure that the law is complied with.