Implementation
PWM generation example
The FXU clock 1 frequency (f
fxclk1
) is 6.250 MHz in this example. The period value to have the
desired PWM frequency (f
PWM
) is calculated with the following formula:



In this example: 
 
 
  
t
t
PWM signal
Period of PWM
FXU clock 1
Frequency of the
clock
Duty cycle of the PWM