261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 05/25/2018
English
Page 26
PRIMARY ELECTROLYTIC CELL CLEANING
SECONDARY ELECTROLYTIC CELL CLEANING
The electrodes have a self cleaning function incorporated into the electronic control’s
programming. In most cases this self cleaning action will keep the electrodes working at optimum
efficiency. If the pool water is hard (high mineral content) the electrodes may require periodic
manual cleaning. To maintain maximum performance, we recommend that you open and visually
inspect the primary and secondary electrodes
(23 & 24)
monthly.
The following steps are some instructions on how to clean your cell.
1.
Switch off the unit, unplug the power cord from the electrical socket.
2.
Disconnect the hose
(12)
from the primary electrolytic cell housing
(22)
outlet and cover the
outlet with the drain outlet cover
(3)
from the 6-way valve
(see drawings 36 and 37)
.
3.
Remove the primary cell from the 6-way valve outlet by unscrewing the electrolytic
cell housing
(22)
collar
(see drawing 38)
.
4.
Pour kitchen grade vinegar into the cell housing to immerse the titanium plates
(see
drawing 39)
. Soak for about 1 hour and then flush with a high-pressure garden hose.
5.
Reverse steps 2 to 4 to reconnect the cell.
1.
Switch off the unit, unplug the power cord from the electrical socket.
2.
In a counter-clockwise motion, unscrew the electrical plug collar from the secondary
electrolytic cell housing, and remove the electrical plug from the secondary cell housing
(see drawings 40 and 41)
.
3.
Unscrew the secondary cell collar
(see drawing 42)
, then remove the secondary cell and
place it on a bucket.
4.
Pour kitchen grade vinegar into the bucket until the secondary cell is immersed
(see
drawing 43)
. Soak for 1 hour and then flush with a high-pressure garden hose.
5.
Reverse steps 2 to 4 to reconnect the secondary electrolytic cell.
41
42
40
43
24
37
36
39
3
22
38
22