1
32
GS
SAVE THESE INSTRUCTIONS
Page 23
(132GS) MODEL CS8220G SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 11/17/2011
English
MMAAIINNTTEENNAANNCCEE
MAINTENANCE (continued)
3. Disconnect the 2 hoses from the Saltwater System, and assemble the cell
cover (10) at each side of the cell.
4. In a counter-clockwise motion, unscrew the collar of the copper electrode (5)
and remove it from the electrolytic cell (4). Lift up the copper electrode.
5. Pour kitchen grade vinegar into the cell to immerse the titanium plates. Then
put the copper electrode back in the cell, soak them for about one hour until
no colored areas remain.
6. Open one side of the cell cover (10), drain and properly dispose of the vinegar.
Connect the hose which goes from the pool to the cell. Flush the cell with the
pool water.
7. Reverse steps 3, 4, 5 and 6 to reconnect the electrolytic cell.