TROUBLESHOOTING (continued)
PROBLEM CAUSE SOLUTION
TUB LOSES AIR
PRESSURE
Air valve cap loose.
Air valve base loose.
Hole, cut or split on spa tub.
Air passage selection dial is not in
the
” position.
Ensure air valve cap is securely closed.
Fill up the spa tub with air then make sure the
air valve base is tighten, see “Spa Tub Air Valve
Fastening” section.
Put liquid soap and water in a squirt bottle and
spray on seams. If there is a leak it will bubble.
After you nd the leak, clean and dry the leaking
area, then apply the repair patch that comes with
your spa.
Always turn the air passage selection dial to
” position after fi nish infl ation fi rst, before
switching off the air bubble pump, so no air
escapes.
LEAKING
BETWEEN
SPA TUB
CONNECTORS
AND CONTROL
UNIT
CONNECTORS
Spa control base inlet/outlet
connections not securely tight.
Spa control base inlet/outlet o-ring
missing/dirty.
Tighten inlet and outlet connections.
Coat the o-ring with petroleum jelly for water
proof.
Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and
not damaged.
SPA IS TOO NOISY
IN FILTRATION
MODE ONLY
Control base components not
securely attached.
Control base ground not level and
rm.
Spa lter motor failed.
Ensure control panel, back cover and all inlet/
outlet are securely connected.
Ensure ground is level, fi rm and smooth.
Replace the failed lter motor with a new one.
INSUFFICIENT
CHLORINE
Insuffi cient operating time of the
sanitation system and/or heater is
running at the same time.
Chlorine loss due to intense sunlight
exposure.
The bather load has increased.
Clogged or dirty electrolytic cell.
Increase the sanitation system operating time
and ensure the heater is off during the sanitation
process. See “Sanitation System Operating
Instructions”.
Use a SPA cover when the SPA is not in use and/
or when the sanitation system is operating.
Increase the sanitation system operating time and
test the water using the test strips. See “Sanitation
System Operating Instructions”.
Check and clean the cell if necessary. See
“Maintenance”.
AIR PRESSURE
IS WEAK DURING
INFLATION
Hose adaptor o-ring missing.
Infl ation hose adaptor not securely
tighten.
Connection between the hose
adaptor and blower infl ation outlet,
and between the infl ation hose and
infl ation valve are loose.
Air blower failure.
Ensure the o-ring is in place.
Tighten/reinstall hose adaptor.
Finger tighten during infl ation.
If problem persists, contact Intex Service Center.
AIR BUBBLES ARE
NOT AS STRONG
AS BEFORE
O-ring missing between the control
base air outlet and spa tub air inlet
connections.
Air connection nut is not securely tight.
Air bubble channel passage inside the
tub broken or leaking.
Air blower failure.
Ensure the o-ring is in place.
Finger tighten all nuts.
Use repair patch to repair any puncture.
If problem persists, contact Intex Service Center.