Function and Features
Copyright ©ITECH Electronic Co., Ltd. 27
Before using analog function, you need to turn on this function in the menu. You
need to set the Ext-C item in the System menu, and select ANA to enable the
external analog control function; select DIGIT to enable the external digital
control function.
The external analog interface terminals: REF_10V , Vs/D0, Is/D1 , D2,
ON/OFF , Vm , Im , NULL , GND correspond to the reference voltage, voltage
control/digital D0, current control/digital D1, digital D2, output on and off control,
voltage monitoring, current monitoring, null pin, and ground.
External analog control interface usage.
You can use three channels of 0~10V analog signal to control voltage, current
and output on/off respectively; and two channels of 0~10V analog signal to
monitor the voltage and current output of power supply.
Detailed terminal descriptions are listed in the table below.
The power supply itself outputs a 10V reference voltage, which
can be connected to a resistor for voltage dividing and used for
Pin2
Vs (voltage
setting)/D0
Voltage control as well as digital input D0 bit.
The voltage control terminal, with an analog input range of
0~10V, can be used to adjust the voltage between 0~voltage
full scale. Taking the IT6942B as an example, when the voltage
input to this terminal is 5V, the corresponding output voltage of
the IT6942B should be 30V.
setting)/D1
Current control terminal and digital input D1 bit.
The current
control terminal, with an analog input range of
0~10V, can be used to adjust the current between 0~current full
scale, take IT6942B as an example, when the input voltage of
this terminal is 1V, the corresponding output current of IT6942B
should be 1.5A.
2
Digital input D2 bit, input 0V (means digital quantity 0) or 10V
(means digital quantity 1).
D2D1D0 combination can input digital quantity 0~7, digital
quantity 0 is invalid input, input digital quantity 1~7 means recall
the parameter in the storage area of Group1~7.
Output on/off control, input analog is 0V or 10V, when input 0V,
power output state is OFF, when input 10V, power output state
Monitor the output voltage.