CS100SUB 150W Powered Sub/ Plate Amp
LINE VOLTAGE Yes/No Hi/Lo Line Unit
Notes
US 120vac/60Hz Yes 108-132 Vrms Normal Operation
EU 230vac/50-60Hz Yes 207-264 Vrms Normal operation, MOMS required
Parameter Specification Unit QA Test Limits Conditions Notes
Amp Section
Type (Class AB, D, other) D D n/a
Load Impedance (speaker) 4 Ohms n/a Nominal
Rated Output Power 150 Watts 145 1 input driven
THD@ Rated Power 0.08 % 1 22K filter
THD @ 1 Watt 0.1 % 0.5 22K filter
DC Offset 10 mV-DC 20 @ Amplifier Output
Damping factor >100 N/A 15 50Hz-4 Ohms load
Measured at amplifier PCB speaker out
connector @ 135 Watts into rated
impedance.
Input Sensitivity
Input Frequency 50 Hz 50 Nominal Freq. 1 input driven
Line Input (L&R) 19.42 mVrms ±2dB To 1 Watt 1 input driven
LFE Input 10.2 mVrms ±2dB To 1 Watt LFE input driven only
Line Input (L & R) Gain 40.25 dB ±1dB 1 input driven
LFE Input Gain 45.84 dB ±1dB LFE input driven only
Signal to Noise
SNR-A-Weighted 100 dBA 85 rel. to rated power A-Weighting filter
SNR-Un-weighted 90 dBr 80 rel. to rated power 22K filter
SNR @ 1W-Un-weighted 60 dBr 60 rel. to 1W Output 22K filter
Residual Noise Floor 1 mVrms 2
Volume @max, using RMS reading
DMM/VOM (or A/P)
Residual Noise Floor 1
mVrms(max)
2
Volume @max, w/ A/P Swept Bandpass
Measurement (Line freq.+ harmonics)
Input Impedance
Line input L&R , LFE >10 K ohms n/a Nominal
Filters
Left & Right Low Pass fixed Hz -- ±2dB
Order & Q 4th dB/Octave n/a
LFE Low Pass fixed Hz -- ±2dB
Order & Q 2nd dB/Octave n/a
Subsonic filter (HPF) Hz -- ±2dB
Order & Q 2nd dB/Octave n/a
Limite
r
(yes/no) YES -- n/a
Features
LFE Input YES Functional BW limited to 500 Hz, refer to ECR00031
Phase Switch (yes/no) YES -- Functional
Volume pot Taper
(
linear/lo
g
LOG -- Functional
ATO (Auto-ON) YES Functional
Input Configuration
Line In (L,R) L ,R -- Functional RCA inputs: L , R
Line level in LFE LFE Functional
Signal Sensing (ATO)
ATO test Frequency 50 Hz
ATO Line Level 2 mV Functional
2mV@50Hz into Line Input w/ 1 ch.
driven
ATO Turn-on time 5 ms Functional
Amp connected and AC on, then input
signal applied in excess of 2mV applied
Auto Mute/ Turn-OFF Time 15 minutes Functional T before muting, after signal is removed
A
uto turn off time
(
T
)
must be
5min > T <15min
Power on Delay time
3 sec. Functional AC Power Applied
Transients/Pops
ATO Transient 5 mV-peak 10 @ Speaker Outputs
Turn-on Transient 50 mV-peak 100 @ Speaker Outputs AC Line cycled from OFF to ON
Turn-off Transient 50 mV-peak 100 @ Speaker Outputs AC Line cycled from ON to OFF
CS100 (CS6100 Subwoofer)