Optional Attachments
Connecting/Disconnecting Hydraulic Hoses
168 168
9811/5700-7
Connecting Quick Release Couplings
1 Remove any residual hydraulic pressure trapped in
the service line hose.
2 Wipe the two faces of the male and female couplings
and make sure they are clean.
3 Make sure that ball C in the female coupling is located
in one of its slots.
4 Fit the male coupling into the female coupling.
5 Where applicable, rotate sleeve E half a turn and
make sure that the locking ball C does not align with
the slot D.
Disconnecting Quick Release Couplings
1 Remove any residual hydraulic pressure trapped in
the service line hose.
2 Where applicable, align the slot D with ball C.
3 Pull back sleeve E to release the coupling.
C007100-1
Fig 133.