3) Select Operating Mode: Press and release [MODE] to change the operating
mode. You can select a different operating mode at any time.
MAX
Maximum
3-Second
Gust Since
Power On
AVG
Average
Wind Speed
Since
Power On
Current
Wind
Speed
4) Select Measurement Scale: Hold down [ON] while pressing [MODE] to change
the measurement scale. You can select a different scale at any time.
Air
Temperature
Wind Chill
SPECIFICATIONS
Wind Speed Functions
Operating Modes: Moving 3-second average ( ), maximum 3-second gust since
power on (MAX) and average since power on (AVG).
Units: Knots (KT), meters per second (M/S), kilometers per hour (KM/H), miles per
hour (MPH), feet per minute (FPM) and Beaufort (B).
On-axis Accuracy: greater of ± 3% or ± least significant digit.
Off-axis Response: -1% @ 5°, -2% @ 10°, -3% @ 15°.
Calibration Drift: < 2% after 100 hours use at 7 M/S [~14 KT, 25 KM/H, 16 MPH or
1400 FPM].
Minimum Speed: 0.3 M/S [~0.6 KT, 1.0 KM/H, 0.7 MPH or 59.0 FPM].
Maximum Speed: 40 M/S [~78 KT, 144 KM/H, 89 MPH or 7877 FPM].
Temperature and Wind Chill Functions
Operating Modes: Temperature ( ), wind chill ( ).
Units: Degrees Centigrade (°C) and degrees Fahrenheit (°F).
Accuracy: ± 1.0°C.
Minimum Temperature: -30°C [-22°F].
Maximum Temperature: 70°C [158°F].
Display
Type: Reflective 3½ digit LCD.
Digit Height: 9 mm. [0.36 in.].
Update: 1 second.
Range and Resolution: Depends
on measurement scale selected –
see chart:
Temperature Limitations: Normal operation from -15°C to 60°C [-4°F to 140°F].
Below -15°C [-4°F], accurate readings may be taken by keeping the unit warmer
than -15°C [4°F] and exposing it for the minimum time necessary to take a reading
(less than one minute).
Auto Shutdown: 30 minutes after last key press.
Environmental
Buttons: Two sealed tactile rubber buttons control all functions.
Battery: User-replaceable CR2032 coin cell. Typical life, 800 hrs.
Sealing: Electronics enclosure IP67 – water resistant to 1 m. [3 ft.]. Floats.
Shock: Drop tested to 2 m. [6 ft.].
Storage Temperature: Prolonged exposure to temperatures below -20°C [-4°F] or
above 80°C [176°F] may cause permanent damage.
Physical
Impeller: 25 mm. [1 in.] diameter, sapphire bearings, light weight. User-replaceable
impeller/housing assembly.
Temperature Sensor: Hermetically sealed precision thermistor.
Case: Slip-on case prevents damage to display and moving parts.
Dimensions: 122 x 42 x 14 mm. [4.8 x 1.7 x 0.6 in.]; case, 117 x 46 x 19 mm. [4.6 x 1.8
x 0.7 in.]; lanyard, 0.5 m. [10 in.].
Weight: Unit, 43 g. [1.5 oz.]; case, 23 g. [0.8 oz.].
5) Measure wind speed, max and average: Simply point the unit into the
air flow you wish to measure.
Measure temperature and wind chill: The Kestrel’s temperature sensor is
located in the right opening below the impeller. Because it is external to the
case, you can take fast and accurate measurements by simply waving the
unit rapidly back and forth OR holding it into an air flow of at least 1 M/S [2
KT, 4 KM/H, 2 MPH or 197 FPM] and reading the display immediately. (The air
flow ensures that the temperature sensor
measures the temperature of the air, not the
case.) Alternatively, you can take accurate
readings with no air flow by allowing the case
to reach the same temperature as the
surrounding air. (If the case is much warmer
or cooler than the air, this can take up to 30
minutes.)
KT
Knots
M/S
Meters per
Second
MPH
Miles per
Hour
KM/H
Kilometers
per Hour
FPM
Feet per
Minute
(x10)
B
Beaufort
Force
°C
Degrees
Centrigrade
°F
Degrees
Fahrenheit
***NOTE***
Select temperature or
wind chill mode to
change degrees.
The Kestrel turns itself off
automatically after 30 minutes
of no button presses.
Scale Range Resolution
KT, M/S, KM/H
MPH, °C & °F 0.0-199.9 0.1
FPM 0-1,999 1
2,000-19,990 10
% 0-100 1
Kestrel
®
2000
Pocket Thermo Wind Meter
OPERATION
1) Slide off Cover. 2) Turn On: Press [ON] to turn on unit.
Wind Speed, Max & Avg Wind Speed, Temperature & Wind Chill
NK