TP-6069 6/0320 Section 6 Electrical System
Amps
Max.
Voltage
Number
of Poles
Model(s)
2
0
250 1 4EFOZ
2
0
600 3 8.5/11.5EFOZ, 14EOZ
22 250 2 4EFOZ, 5EOZ
25 250 2 5EOZ
2
5
0
1 6.5EFOZ
3
0
2
5
0
2 6.5EFOZ
3
0
600 3
11.5/17.5/20EFOZ,
14/20/24EOZ—3 phase
33 250 2 8EOZ
3
5
2
5
0
1 4EFOZ
3
5
2
5
0
2 8EOZ
250 1 5EOZ
40
600 3
11.5EFOZ,
14/20/24EOZ—3 phase
4
2
2
5
0
1 9EFOZ
4
2
2
5
0
2 9EFOZ, 8/10EOZ
2
4
0
1 11/13EFOZ
2
4
0
2 11/11.5/17.5EFOZ
50
250 2 9EFOZ, 10EOZ
480 3
20/23/27EFOZ,
20/28/32EOZ—3 phase
55 250 1 5EOZ
2
4
0
1 13EFOZ
2
4
0
2 11/13EFOZ, 13/14EOZ
60
250 1 6.5EFOZ
600 3
17.5/20EFOZ,
20/24/28/32EOZ—3 phase
2
4
0
1 16EFOZ
7
0
2
4
0
2 13/20EFOZ, 15.5EOZ
7
0
250 1 6.5EFOZ, 8EOZ
600 3 20/24EOZ—3 phase
1 16/19EFOZ
80
240
2
16EFOZ, 20EOZ—1 phase,
20/24EOZ—3 phase
8
0
250 1 8EOZ
480 3 23EFOZ—3 phase
85 250 1 9EFOZ, 10EOZ
1 19EFOZ
90
240
2
19EFOZ—1 phase
20/23EOZ
480 3 27EFOZ—3 phase
240 2 23EOZ
100
480 3
23/27EFOZ,
28/32EOZ—3 phase
1
2
5
6
0
0
2
23/27EFOZ, 28EOZ—
1 phase, 27EFOZ—3 phase
1
2
5
6
0
0
3
23/27EFOZ,
28/32EOZ—3 phase
150 600 2
28/32EOZ—1 phase,
32EOZ— 3 phase
175 600 2 32EOZ—1 phase
Figure 6-2 AC Circuit Breaker Ratings (4--27EFOZ
and 5--32EOZ Models), Listed By Amps
Amps
Max.
Voltage
Number
of Poles
Type Model(s)
60 600 3 UL/IEC 33EFOZ, 40EOZ
70 600 3 UL/IEC 40EFOZ, 40EOZ
80 480 3 UL/IEC 40EFOZ, 50EOZ
100 480 3 UL/IEC 55EFOZ, 50/65EOZ
100--125 600 3 IEC
33/55EFOZ,
40/65EOZ
100--125 600 3 IEC 70EFOZ, 80EOZ
125 600 3 UL
33/55EFOZ,
40/65EOZ
125 600 3 UL 70EFOZ, 80EOZ
128--160 600 3 IEC
33/40EFOZ,
40/50EOZ
128--160 600 3 IEC
70/80EFOZ,
80/99EOZ
150 600 3 UL
33/40EFOZ,
40/50EOZ
150 600 3 UL
70/80EFOZ,
80/99EOZ
160--400 600 3 UL
70/80/100EFOZ,
80/99/125/150EOZ
160--400 600 3 IEC
70/80/100/125EFOZ,
80/99/125/150EOZ
200 600 3 UL
40/55EFOZ,
50/65EOZ
200 600 3 UL
100EFOZ,
99/125EOZ
200--250 600 3 IEC
40/55EFOZ,
50/65EOZ
200--250 600 3 IEC
70/100/125EFOZ,
80/125/150EOZ
240--600 600 3 UL
125EFOZ,
125/150EOZ
250 600 3 UL 55EFOZ, 65EOZ
250 600 3 UL
70/125EFOZ,
80/125/150EOZ
250--630 600 3 IEC
125EFOZ,
125/150EOZ
Figure 6-3 AC Circuit Breaker Ratings (33--150 kW
Models), Listed By Amps
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working on the generator set.
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
WARNING

Other manuals for Kohler 17.5EFOZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 17.5EFOZ and is the answer not in the manual?

Kohler 17.5EFOZ Specifications

General IconGeneral
BrandKohler
Model17.5EFOZ
CategoryPortable Generator
LanguageEnglish

Related product manuals