1.13
Section 1
Safety and General Information
1
Valves and Valve Lifters
Hydraulic Valve Lifter to Crankcase Running Clearance .......... 0.0124/0.0501 mm (0.0005/0.0020 in.)
Intake Valve Stem-to-Valve Guide Running Clearance ............ 0.038/0.076 mm (0.0015/0.0030 in.)
Exhaust Valve Stem-to-Valve Guide Running Clearance ......... 0.050/0.088 mm (0.0020/0.0035 in.)
Intake Valve Guide I.D.
New .................................................................................... 7.038/7.058 mm (0.2771/0.2779 in.)
Max. Wear Limit ................................................................. 7.134 mm (0.2809 in.)
Exhaust Valve Guide I.D.
New .................................................................................... 7.038/7.058 mm (0.2771/0.2779 in.)
Max. Wear Limit ................................................................. 7.159 mm (0.2819 in.)
Valve Guide Reamer Size
STD .................................................................................... 7.048 mm (0.2775 in.)
0.25 mm O.S. ..................................................................... 7.298 mm (0.2873 in.)
Intake Valve Minimum Lift ......................................................... 8.96 mm (0.353 in.)
Exhaust Valve Minimum Lift ..................................................... 9.14 mm (0.360 in.)
Nominal Valve Seat Angle ........................................................ 45°