Required Electrical Service
One dedicated circuit required, protected with Class A Ground-
Fault Circuit-Interrupter (GFCI). Outside North America, this
device may be known as a Residual Current Device (RCD).
120 V, 7.25 A, 60 Hz
Technical Information
All product dimensions are nominal.
Seat shape type: Elongated
Seat front type: Closed-front
Seat-mounting
holes:
5-1/2" (140 mm)
Power cord length: 47-1/4" (1200 mm)
Notes
Install this product according to the installation
instructions.
To avoid possible product malfunction, do not
plug in the seat until instructed to do so.
Locate the recepticle at least 6" (152 mm)
above the floor, and within a 32" (813 mm)
radius measured 2" (51 mm) from the bowl
ledge.
Do not use an extension cord with this product.
Do not install this seat in a location where: (1)
water might be splashed on the product or
(2) excessive moisture, high humidity levels,
or condensation is present. This will avoid
damage to the electronic components.
Kohler Co. reserves the right to make revisions without notice to product specifications.