DE
FRNL
IT
EN
39
ENGLISH
KRUPS SERIE EA9000
38
n Cleaning the steam nozzle cleaning container
n Cleaning the ground coffee funnel
2
n Open the ground coffee funnel lid.
n Remove the ground coffee funnel.
1
n You can access the “Maintenance” menu from the main menu
by pressing the “Maintenance” tab.
n You cannot clean the ground coffee funnel without going through the
Maintenance tab. Always follow the instructions given on the screen.
n Press the “Cleaning the ground coffee funnel” button on the touch
screen.
n The ground coffee funnel lid is then unlocked.
n To quit the “Maintenance” menu, press the “Maintenance” tab.
3
n Clean the ground coffee funnel.
n You can clean it with the brush or under running water. Caution: Dry
it thoroughly. It must be dry when you replace it.
9
n Replace the two drip trays (see visuals p. 13).
n The manual steam nozzle cleaning cycle is finished.
n Press OK to confirm and quit.
h
Caution: The manual cleaning of the nozzle and the cleaning container must be carried out in this
sequence: If not, you risk damage to the steam nozzle assembly, malfunction or breakage.
!
Caution: Do not force the funnel open; it is always locked when the recipes are prepared.
!
n You can access the “Maintenance” menu from the main menu
by pressing the “Maintenance” tab.
n To clean the nozzle and its container, you must follow the sequence
shown in the Maintenance tab.
n Failure to follow this sequence may damage the system.
n Press the “Cleaning container” button on the touch screen.
n Then follow the instructions on the screen, referring to the visuals in
step 9 in the manual cleaning of the nozzle until you see the screen
on the right.
n This cleaning cycle is finished.
6
n The steam tube moves down.
n You can thus clean it properly with a damp cloth (you can use a little
washing-up liquid, but rinse it thoroughly). The steam tube cannot be
dismantled.
n Press the “OK” button. The steam tube moves up so that the nozzle tip
and the nozzle can be refitted.
7
n Re-screw the nozzle with the tip onto the steam tube.
n Press the “OK” button.
n The steam nozzle assembly moves up and stops above the cleaning
container.
8
n Cleaning the steam nozzle cleaning container (11).
n Press YES to the question: “Do you want to clean your cleaning container?”
if you want to clean it.
n Press the top of the container to remove it. Clean it under running water.
n To put the container back, first position the lower part and then press the
upper part: you should hear a “click”.
n Press the “OK” button.
hh