2T6/2T7/2T8/2T9
2-4-4
Printing concentration D4 1: Thin.
2: Slightly Thin.
3: Standard
4: Slightly Deep.
5: Deep.
3
Total host buffer size H8 0 to 99 in units of the size defined by FRPO S5 5
Form feed time-out value H9 Value in units of 5 seconds (1 to 99). 1
KIR mode N0 0: Off
2: On
2
Duplex binding N4 0: Off
1: Long edge
2: Short edge
0
Sleep timer time-out time N5 1 to 240 minutes [0: Off] 1
Ecoprint level N6 0: Off
2: On
0
Resolution N8 0: 300dpi
1: 600dpi
3: 1200dpi
1
Parallel interface mode O0 0: Standard Mode
1: Fast Mode
5: Nibble (High Speed) Mode
70: Automatic Mode
70
Parallel interface Error control O2 0: Line Control OFF
2: Compatibility with PCL
2
Default emulation mode P1 0 : Line printer
1 : IBM proprinter
2 : DIABLO 630
5 : Epson LQ-850
6 : PCL6 (except PCL XL)
8 : KC-GL
9 : KPDL
11 : PC-PR201
12 : IBM 5577
13 : VP-1000
14 : N5200
15 : FMPR-359F1
6
9(U.S.A)
Carriage-return action * P2 0: Ignores 0x0d
1: Carriage-return
2: Carriage-return+linefeed
1
Linefeed action * P3 0: Ignores 0x0d
1: Linefeed
2: Linefeed+carriage-return
1
Item FRPO Setting values
Factory
setting