7
90027911rev04
2 • TECHNICAL DATA
7
90027911rev04
TABLE 2: GENERAL DATA GAS OVENS
Model
Supply
voltage
Frequency
(**)
Imput Motor
Oil-proof
connection cable
( * )
Gas power
w/boiler
Gas power
w/o boiler
Gas
connection
NAGB071.
SAGB071.
AC 230 V 50/60 Hz 0,5 kW 1 x 0,37 kW 3 x 1 mm
2
15 kW - 1 x R 1/2”
NAGV071.
ARGN064.
SAGV071.
ARGS064.
AC 230 V 50/60 Hz 0,5 kW 1 x 0,37 kW 3 x 1 mm
2
- 12 kW 1 x R 1/2”
NAGB101.
SAGB101.
AC 230 V 50/60 Hz 1 kW 1 x 0,55 kW 3 x 1 mm
2
28 kW - 1 x R 1/2”
NAGV101.
ARGN084.
SAGV101.
ARGS084.
AC 230 V 50/60 Hz 1 kW 1 x 0,55 kW 3 x 1 mm
2
- 18 kW 1 x R 1/2”
NAGB072.
SAGB072.
AC 230 V 50/60 Hz 1 kW 1 x 0,55 kW 3 x 1 mm
2
30 kW - 1 x R 1/2”
NAGV072.
SAGV072.
AC 230 V 50/60 Hz 1 kW 1 x 0,55 kW 3 x 1 mm
2
- 20 kW 1 x R 1/2”
NAGB102.
SAGB102.
AC 230 V 50/60 Hz 1 kW 1 x 0,55 kW 3 x 1 mm
2
40 kW - 1 x R 1/2”
NAGV102.
SAGV102.
AC 230 V 50/60 Hz 1 kW 1 x 0,55 kW 3 x 1 mm
2
- 27 kW 1 x R 1/2”
NAGB171.
SAGB171.
AC 230 V 50/60 Hz
0,5 kW
+
1 kW
1 x 0,37 kW
+
1 x 0,55 kW
3 x 1,5 mm
2
43 kW - 2 x R 1/2”
NAGM171.
SAGM171.
AC 230 V 50/60 Hz
0,5 kW
+
1 kW
1 x 0,37 kW
+
1 x 0,55 kW
3 x 1,5 mm
2
28 kW 12 kW 2 x R 1/2”
NAGV171.
ARGN144.
SAGV171.
ARGS144.
AC 230 V 50/60 Hz
0,5 kW
+
1 kW
1 x 0,37 kW
+
1 x 0,55 kW
3 x 1,5 mm
2
- 30 kW 2 x R 1/2”
NAGB201.
SAGB201.
AC 230 V 50/60 Hz 1,8 kW 2 x 0,55 kW 3 x 1,5 mm
2
48 kW - 1 x R 3/4”
NAGV201.
ARGN154.
SAGV201.
ARGS154.
AC 230 V 50/60 Hz 1,8 kW 2 x 0,55 kW 3 x 1,5 mm
2
- 36 kW 1 x R 3/4”
NAGB202.
SAGB202.
AC 230 V 50/60 Hz 1,8 kW 2 x 0,55 kW 3 x 1,5 mm
2
80 kW - 1 x R 3/4”
NAGV202.
SAGV202.
AC 230 V 50/60 Hz 1,8 kW 2 x 0,55 kW 3 x 1,5 mm
2
- 54 kW 1 x R 3/4”
Caution: The residual current device to be installed between the mains and the appliance
must be sized for a leakage of 1 mA x kW of power installed.
( * ) Flexible cable underneath sheath resistant to oil with designation 60245-IEC-57
(**) for ovens compatible with operation at a frequency of 60 Hz, the data is the same. Always check the frequency shown
on the technical data label afxed to the appliance.