EasyManuals Logo
Home>Lennox>Furnace>80UHG2-45

Lennox 80UHG2-45 User Manual

Lennox 80UHG2-45
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
1999 Lennox Industries Inc.
Litho U.S.A.
Corp. 9728−L12
80UHG
Service Literature
Revised 01−2002
80UHG series units are mid−efficiency gas furnaces used
for upflow or horizontal applications only, manufactured
with tubular heat exchangers formed of aluminized steel.
80UHG units are available in heating capacities of 45,000
to 120,000 Btuh and cooling applications up to 5 tons. Refer
to Engineering Handbook for proper sizing.
Units are factory equipped for use with natural gas. Kits are
available for conversion to LPG operation. 80UHG−1 model
units use electronic (direct spark) ignition. 80UHG−2 and −3
model units are equipped with the Lennox SureLight silicon
nitride ignition system. The 80UHGX unit meets the Califor
nia Nitrogen Oxides (NO
x
) Standards and California Sea
sonal Efficiency requirements. All units use a redundant gas
valve to assure safety shut−off as required by A.G.A. or
C.G.A. Units may be installed in upflow or horizontal posi
tion.
All specifications in this manual are subject to change. Pro
cedures outlined in this manual are presented as a recom
mendation only and do not supersede or replace local or
state codes. In the absence of local or state codes, the
guidelines and procedures outlined in this manual (except
where noted) are recommended only and do not constitute
code.
TABLE OF CONTENTS
Introduction 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Data 3−4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Altitude 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Identification 5−6. . . . . . . . . . . . . . . . . . . . . . . . . . . .
I Unit Components 6−15. . . . . . . . . . . . . . . . . . . . . . . . . . .
II Installation 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
III Start Up 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IV Heating System Service Checks 16−17. . . . . . . . . . .
V Typical Operating Characteristics 18. . . . . . . . . . . . . .
VI Maintenance 19−20. . . . . . . . . . . . . . . . . . . . . . . . . . . .
VII Wiring and Sequence of Operation 21−28. . . . . . . . .
VIII SureLight Troubleshooting Guide 29−34. . . . . . . . . .