OPTIONS / ACCESSORIES
Item Description
Catalog
Number
Unit Model No
156 180 210 240 300
CONTROLS
Blower Proving Switch 21Z10 OX OX OX OX OX
Commercial
Controls
Prodigy
®
Control System - BACnet
®
Module  OX OX OX OX OX
Prodigy
®
Control System - LonTalk
®
Module 54W27 OX OX OX OX OX
Novar
®
LSE Factory O O O O O
Dirty Filter Switch 53W68 OX OX OX OX OX
Fresh Air Tempering 58W63 OX OX OX OX OX
General Purpose Control Kit 13J78 X X X X X
Smoke Detector - Supply or Return (Power board and one sensor) 22H56 OX OX OX OX OX
Smoke Detector - Supply and Return (Power board and two sensors) 22H57 OX OX OX OX OX
INDOOR AIR QUALITY
Air Filters
Healthy Climate
®
󰀩
24 x 24 x 2 (Order 6 per unit)
MERV 8 54W67 OX OX OX OX OX
MERV 13 52W40 OX OX OX OX OX
Replacement Media Filter With Metal Mesh Frame

44N61 OX OX OX OX OX

󰀨 77N39 X X X X X
󰀨 87N53 X X X X X
Sensor - Black plastic case with LCD display, rated for plenum mounting 87N52 X X X X X
Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting 87N54 X X X X X
CO 85L43 X X X X X
Aspiration Box - for duct mounting non-plenum rated CO sensors
(87N53 or 77N39)
90N43 X X X X X
Needlepoint Bipolar Ionization (NPBI)
Needlepoint Bipolar Ionization (NPBI) Kit 21U37 X X X
21U38 X
21U39 X
UVC Germicidal Light Kit
1
Healthy Climate
®
UVC Light Kit (110/230v-1ph) 21A94 X X X X X
Step-Down Transformers 460V primary, 230V secondary 10H20 X X X X X
575V primary, 230V secondary 10H21 X X X X X
ELECTRICAL
Voltage 60 hz 208/230V - 3 phase Factory O O O O O
460V - 3 phase Factory O O O O O
575V - 3 phase Factory O O O O O
HACR Circuit Breakers Factory O O O O O
² Short-Circuit Current Rating (SCCR) of 100kA (includes Phase/Voltage Detection) Factory O O O O O
Disconnect Switch
(see Disconnect Table for usage, page 51)
80 amp 54W88 OX OX OX OX OX
150 amp 54W89 OX OX OX OX OX
250 amp 90W82 OX
GFI Service
Outlets
 74M70 OX OX OX OX OX
15 amp factory-wired and powered (208/230V, 460V, 575V) Factory O O O O O
 67E01 OX OX OX OX OX
Weatherproof Cover for GFI 10C89 X X X X X
Phase/Voltage Detection (Optional for CAV options only, furnished with MSAV
®
option) Factory O O O O O
1
Lamps operate on 110-230V single-phase power supply. Step-down transformer may be ordered separately for 460V and 575V units. Alternately, 110V power supply
may be used to directly power the UVC ballast(s).
2
Disconnect Switch is furnished and factory installed with High SCCR option.



X = Field Installed