Table 1. Troubleshooting
Symptom Possible Cause Possible Solution
Unit does not start.
Power failure
Power to unit is OFF or disconnected
Circuit breaker may be tripped or fuse may be
blown
Wireless remote control batteries may have
lost their charge or unit controller may have
malfunctioned
Wait for power to be restored
Turn on or reconnect power to the unit
Reset circuit breaker or replace fuse
Replace AAA size batteries in wireless remote
control. Check controller for proper function
Indoor fan is operating; however, air is
not cool.
Temperature not properly set at con trol
Compressor may be kept off by delay
Check temperature setting at control
Wait for delay to expire
Unit cycles on and off frequently.
Refrigerant charge is incorrect
Air in refrigerant circuit
Compressor malfunction
Improper voltage
System refrigerant circuit is blocked
Check for refrigerant leaks and prop erly charge
system
Evacuate and properly charge system
Check compressor and replace, if ne cessary
Check with utility company to provide proper
voltage
Clear blockage
Unit not cooling properly.
Indoor and/or outdoor coil are dirty
Air lter is dirty
Air ow around indoor and/or outdoor unit is
obstructed
Doors and/or windows are open
Direct sunlight is affecting indoor tem perature
Heat source inside is placing a large burden on
the system
Suction pressure is low due to possible refrig-
erant leak
Clean indoor and/or outdoor coil
Clean or replace air lter
Remove obstructions
Close doors and windows
Use curtains or blinds to block direct sunlight.
Reduce burden of heat source
Check for refrigerant leaks and prop erly charge
system
Unit not heating properly.
Doors and/or windows are open
Suction pressure is low due to possible refrig-
erant leak
Close doors and windows
Check for refrigerant leaks and prop erly charge
system
Fan speed cannot be changed.
Check the mode listed on the unit dis play. Fan
speed cannot be changed in the AUTO or DRY
mode
Fan speed cannot be changed in AUTO or DRY
mode. Change mode to COOL, FAN ONLY or HEAT.
Wireless remote control signal is not
being trans mitted, even when ON/OFF
button is pressed.
Batteries may have lost their charge Replace AAA size batteries (2)
The TEMP adjustment indicator is not
available.
Check the mode listed on the unit dis play.
Temperature cannot be adjusted in the FAN ONLY
mode
Change the mode to COOL, HEAT or DRY
Operation indicator disappears from
the display after a period of time.
Check to see if display reads TIMER OFF
Timed operation is terminated at the end of the
TIMER period
TIMER ON disappears from the display
after a period of time.
Check to see if display reads TIMER OFF
Timed operation is terminated when time period has
expired.
No tones being sounded by indoor unit,
even when ON/OFF button is pressed.
Infra-red receiver must be able to see signal
from wireless remote control
Batteries may have lost their charge
Aim wireless remote control infra-red transmit ter
directly at receiver
Replace AAA size batteries (2)