EasyManuals Logo
Home>Lennox>Furnace>ML180UH110E60C

Lennox ML180UH110E60C User Manual

Lennox ML180UH110E60C
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Page 8
TABLE 1
4-Pin Terminal Designation
PIN # FUNCTION
1 Combustion Air Inducer Line
2 Ignitor Line
3 Combustion Air Inducer Neutral
4 Ignitor Neutral
TABLE 2
12-Pin Terminal Designations
PIN # FUNCTION
1 High Limit Output
2 Not Used
3 24V Line
4 Not Used
5 Rollout Switch Out
6 24V Neutral
7 High Limit Input
8 Ground
9 Gas Valve Common
10 Pressure Switch In
11 Rollout Switch In
12 Gas Valve Out
TABLE 3
1/4” Quick Connect Terminals
120HUM Humidier 120VAC
LINE 120VAC
XFMR Transformer 120VAC
CIRC Indoor blower 120VAC
EAC Indoor air quality accessory 120VAC
NEUTRALS Common 120VAC
HUM24 Humidier 24VAC
3/16” Quick Connect Terminals
COOL Cooling tap 24VAC
HEAT Heating tap 24VAC
FAN Continuous blower 24 VAC
PARK
(no power)
Park terminal for speed taps
FS Flame sense
24 COM Common 24VAC
INTEGRATED CONTROL
(Automatic Hot Surface Ignition System)
BLOWER OFF DELAY
RED LED
RECALL BUTTON
FIGURE 3

Other manuals for Lennox ML180UH110E60C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox ML180UH110E60C and is the answer not in the manual?

Lennox ML180UH110E60C Specifications

General IconGeneral
BrandLennox
ModelML180UH110E60C
CategoryFurnace
LanguageEnglish

Related product manuals