XC14 - 1.5 to 5 Ton Air Conditioner / Page 13
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC14-024-230 TXV 23,000 13.50 11.50 C33-30 3131779
XC14-024-230 TXV 24,600 16.00 13.20 C33-31 G61MPV-36B-045 3131791
XC14-024-230 TXV 24,600 16.00 13.20 C33-31 G61MPV-36B-070 3131792
XC14-024-230 TXV 24,600 16.00 13.20 C33-31 G61MPV-36B-071 3131793
XC14-024-230 TXV 24,600 16.20 13.50 C33-31 SL280UH070V36A 4035244
XC14-024-230 TXV 24,600 16.20 13.50 C33-31 SL280UH070XV36A 4037846
XC14-024-230 TXV 24,800 16.20 13.50 C33-31 SL280UH090V36B 4035245
XC14-024-230 TXV 24,600 16.50 13.70 C33-31 SLP98UH070V36B 4020353
XC14-024-230 TXV 24,000 14.00 12.00 C33-31 3131788
XC14-024-230 TXV 24,200 15.70 13.00 C33-36 G61MPV-36B-045 3131798
XC14-024-230 TXV 24,200 15.70 13.20 C33-36 G61MPV-36B-070 3131799
XC14-024-230 TXV 24,200 15.70 13.20 C33-36 G61MPV-36B-071 3131800
XC14-024-230 TXV 24,000 15.50 13.00 C33-36 G61MPV-36C-090 3131801
XC14-024-230 TXV 24,200 15.70 13.20 C33-36 SL280UH070V36A 4035246
XC14-024-230 TXV 24,200 15.70 13.20 C33-36 SL280UH070XV36A 4037847
XC14-024-230 TXV 24,400 16.00 13.20 C33-36 SL280UH090V36B 4035247
XC14-024-230 TXV 24,200 16.00 13.50 C33-36 SLP98UH070V36B 4020354
XC14-024-230 TXV 24,200 16.20 13.50 C33-36 SLP98UH090V36C 4020355
XC14-024-230 TXV 23,600 13.70 11.70 C33-36 3131795
XC14-024-230 TXV 24,600 15.70 13.20 C33-38 G61MPV-36B-045 3131807
XC14-024-230 TXV 24,400 16.00 13.20 C33-38 G61MPV-36B-070 3131808
XC14-024-230 TXV 24,400 16.00 13.20 C33-38 G61MPV-36B-071 3131809
XC14-024-230 TXV 24,800 16.20 13.70 C33-38 SL280UH070V36A 4035248
XC14-024-230 TXV 24,800 16.20 13.70 C33-38 SL280UH070XV36A 4037848
XC14-024-230 TXV 24,600 16.20 13.70 C33-38 SL280UH090V36B 4035249
XC14-024-230 TXV 24,800 16.50 13.70 C33-38 SLP98UH070V36B 4020356
XC14-024-230 TXV 24,200 14.20 12.00 C33-38 3131804
XC14-024-230 TXV 23,800 14.50 12.20 CB26UH-024 3131811
XC14-024-230 TXV 23,800 14.50 12.20 CBX26UH-024 3131819
XC14-024-230 TXV 24,400 16.00 13.20 CBX27UH-024 3131820
XC14-024-230 TXV 24,600 16.20 13.50 CBX27UH-030 3131821
XC14-024-230 TXV 23,600 14.20 11.70 CBX32M-018/024 3131822
XC14-024-230 TXV 24,200 14.70 12.50 CBX32M-030 3131823
XC14-024-230 TXV 25,400 15.20 12.70 CBX32M-036 3131824
XC14-024-230 TXV 23,800 14.50 12.00 CBX32MV-018/024 3131825
XC14-024-230 TXV 24,400 16.00 13.00 CBX32MV-024/030 3131826
XC14-024-230 TXV 24,800 16.00 13.00 CBX32MV-036 3131827
XC14-024-230 TXV 23,800 14.50 12.00 CBX40UHV-024 3291606
XC14-024-230 TXV 24,400 16.00 13.00 CBX40UHV-030 3291626
XC14-024-230 TXV 24,800 16.00 13.00 CBX40UHV-036 3291675
XC14-024-230 TXV 22,400 13.20 11.20 CH23-31 3131828
XC14-024-230 TXV 23,600 14.00 11.70 CH23-41 3131829
XC14-024-230 TXV 23,800 15.70 13.20 CH33-19 SL280UH070V36A 3929104
XC14-024-230 TXV 23,800 15.70 13.20 CH33-19 SL280UH070XV36A 4037837
XC14-024-230 TXV 23,200 13.70 11.50 CH33-19 3131831
XC14-024-230 TXV 23,800 15.20 13.00 CH33-24/30 SL280UH070V36A 3929105
XC14-024-230 TXV 23,800 15.20 13.00 CH33-24/30 SL280UH070XV36A 4037838
XC14-024-230 TXV 23,200 13.50 11.50 CH33-24/30 3131833
XC14-024-230 TXV 24,400 15.70 13.20 CH33-25 SL280UH070V36A 3929106
XC14-024-230 TXV 24,400 15.70 13.20 CH33-25 SL280UH070XV36A 4037839
XC14-024-230 TXV 24,000 16.00 13.20 CH33-25 SL280UH090V36B 3929107
XC14-024-230 TXV 24,200 16.00 13.50 CH33-25 SLP98UH070V36B 4020365
XC14-024-230 TXV 23,800 14.00 11.70 CH33-25A 3131834
XC14-024-230 TXV 24,200 15.70 13.00 CH33-25B G61MPV-36B-045 3131836
XC14-024-230 TXV 24,200 15.70 13.20 CH33-25B G61MPV-36B-070 3131837
XC14-024-230 TXV 24,200 15.70 13.20 CH33-25B G61MPV-36B-071 3131838
XC14-024-230 TXV 23,600 13.70 11.70 CH33-25B 3131840
XC14-024-230 TXV 24,800 16.00 13.50 CH33-31 SL280UH070V36A 3929108
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.