10 Parameter reference
10.2 Parameter list | C00150
257
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00150
Parameter | Name:
C00150 | Status word
Data type: UNSIGNED_16
Index: 24425
d
= 5F69
h
Bit-coded device status word
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 FreeStatusBit0 Free status bit 0
Bit 1 PowerDisabled Power switched off
Bit 2 FreeStatusBit2 Free status bit 2
Bit 3 FreeStatusBit3 Free status bit 3
Bit 4 FreeStatusBit4 Free status bit 4
Bit 5 FreeStatusBit5 Free status bit 5
Bit 6 ActSpeedIsZero Current speed is 0
Bit 7 ControllerInhibit Controller is inhibited
Bit 8 StatusCodeBit0 Status code bit 0
Bit 9 StatusCodeBit1 Status code bit 1
Bit 10 StatusCodeBit2 Status code bit 2
Bit 11 StatusCodeBit3 Status code bit 3
Bit 12 Warning Warning
Bit 13 Trouble Fault
Bit 14 FreeStatusBit14 Free status bit 14
Bit 15 FreeStatusBit15 Free status bit 15
Read access Write access CINH PLC STOP No transfer COM MOT