28803 0x7083 HTL input fault Keypad display: HTL input fault
Cause Error type/response Remedy
The monitoring of the input signal congured
for the HTL input has been triggered.
No response
The error type can be congured in
0x2641:006 (P416.06).
Check input signal at the HTL input.
Check conguraon of the monitoring func-
on.
Related topics
4HTL input setpoint source ^ 565
28833 0x70A1 Analog output 1 fault Keypad display: AO1 fault
Cause Error type/response Remedy
Open circuit or short circuit at analog output 1. Warning
Check wiring of analog output 1.
Check denion of the output range in
0x2639:001 (P440.01).
Related topics
4Analog output 1 ^ 617
28834 0x70A2 Analog output 2 fault Keypad display: AO2 fault
Cause Error type/response Remedy
Open circuit or short circuit at analog output 2. Warning
Check wiring of analog output 2.
Check denion of the output range in
0x263A:001 (P441.01).
Related topics
4Analog output 2 ^ 620
28961 0x7121 Pole posion idencaon fault Keypad display: Pole pos. error
Cause Error type/response Remedy
Too many deviaons during the pole posion
idencaon.
Compared to the inverter, the rated motor
current is too high or too low.
Fault
The inverter is inhibited immediately. The
motor becomes torqueless (coasts).
The error type can be congured in 0x2C60.
Check seng of the motor data.
Ensure that the motor is at a standsll during
the pole posion idencaon process.
Ensure that the motor and inverter match
each other in terms of power.
29056 0x7180 Motor overcurrent Keypad display: Mot max current
Cause Error type/response Remedy
The motor current has exceeded the warning/
error threshold for the motor current monitor-
ing set in 0x2D46:001 (P353.01).
Fault
The error can only be reset aer a blocking
me of 1 s.
The error type can be congured in
0x2D46:002 (P353.02).
Check motor load.
Check drive dimensioning.
Check warning/error threshold set in
0x2D46:001 (P353.01).
Related topics
4Overcurrent monitoring ^ 222
29445 0x7305 Encoder open circuit Keypad display: Encoder error
Cause Error type/response Remedy
The encoder signal loss monitoring funcon has
detected a failure of the encoder signal.
Warning
The error type can be congured in 0x2C45
(P342.00).
Check the encoder connecon.
Check encoder cable for wire breakage.
Check encoder current supply.
Related topics
4Encoder monitoring ^ 498
Appendix
Error codes
648

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55 Series and is the answer not in the manual?

Lenze i55 Series Specifications

General IconGeneral
BrandLenze
Modeli55 Series
CategoryInverter
LanguageEnglish

Related product manuals