Electronic Countdown Timer Switch (Single Pole)
Cat. Nos. DT115, DT130, DT160, DT102, DT104, DT112 Lighted
Ratings: 15 A Resistive, 1,800 W Incandescent/Halogen, 600 W LED/CFL,
1,200 VA ELV/MLV/Fluorescent, 1/2 HP or 9.8 A Motor/Fan, 120 VAC, 60 Hz
INSTALLATION INSTRUCTIONS
ENGLISH
PK-A3460-10-00-2A
CAUTIONS:
• DO NOT use disinfecting products, including foggers, sprays or other types of atomized
cleaning agents.
DO NOT spray liquid onto the product.
To clean, use a damp cloth with mild soap.
No user serviceable components. DO NOT attempt to service or repair.
Use this device WITH COPPER OR COPPER-CLAD WIRE ONLY.
Installation
WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn OFF power at circuit
breaker or fuse and test that the power is OFF before wiring!
1. Identify your wires (most common shown).
NOTE: A Neutral wire (if present) or a Ground wire is required for
operation. If the wiring in the wallbox does not resemble this configuration,
consult an electrician.
You Will Need:
• Slotted/Phillips screwdriver
• Electrical tape
• Cutters
• Pliers
Features
Easy operation with four preset buttons and one "OFF" button.
Simple press and hold override function for 24-hour override.
• For Single-Pole wiring only.
With Zero Cross turn-ON technology that extends the life of the switching
relays (turns ON at the minimum voltage).
Color change kits are available in white, light almond, ivory, black, brown, and
gray (DTKIT-00x).
Available with six countdown timer options (15, 30, 60 minutes, and 2, 4, 12 hours).
Available in a 20A larger load, multi-way, or multi-timer (Cat. No. DT2xx).
No Neutral Wire With Neutral Wire
LOAD
LINE
GROUND
To and From Load
From
Branch Circuit
LOAD
LINE
GROUND
NEUTRAL
To Load
2a. Wire device (when Neutral is NOT present).
Work on one connection at a time, and connect wires as shown.
NOTE: This device is designed so that the line and load wires can be
wired interchangeably.
LINE
GROUND
(Green/Yellow)
LINE/LOAD
(Black)
GROUND
To and From
To and From
Light/Load
Light/Load
LOAD
GROUND
(Green sleeved wire)
GROUND
GRN/YL
LINE/LOAD
BLACK
LINE/LOAD
BLACK
GROUND
GRN SLEEVE
NEUTRAL
WHITE
LINE/LOAD
(Black)
LINE
GROUND
(Green/Yellow)
LINE/LOAD
(Black)
LOAD
GROUND
To and From
To and From
Light/Load
Light/Load
NEUTRAL
(White)
NEUTRAL
LINE/LOAD
(Black)
GROUND
GRN/YL
LINE/LOAD
BLACK
LINE/LOAD
BLACK
GROUND
GRN SLEEVE
NEUTRAL
WHITE
2b. Wire device (when Neutral is present).
Remove the green sleeve from the white wire.
• Work on one connection at a time, and connect the wires as shown.
NOTE: This device is designed so that the line and load wires can be
wired interchangeably.
WARNINGS:
TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a
receptacle, or a load in excess of the specified rating.
DO NOT use to control lighting if it is the only light source in the area.
To be installed and/or used in accordance with electrical codes and regulations.
If you are not sure about any part of these instructions, consult an electrician.