ENGLISH
BEFORE CALLING FOR SERVICE (cont.)
Problem Possible Causes Solutions
Steam doesn’t
generate but no error
code is shown
• Waterlevelerror.
• Unplugdryerandcallforservice.
Garments still
wrinkled after
STEAM FRESH
™
• Toomanyortoodifferent
typesofgarmentsindryer.
• Smallloadsof1to5itemsworkbest.
• Loadfewergarments.Loadsimilar-typegarments.
There are no creases
left on garment after
STEAM FRESH
™
• Thefunctionofthiscycle
istoremovewrinklesfrom
fabric.
• Useanirontomakecreases.
Garments have
static after REDUCE
STATIC
• Thisisnormal.
• Dependsonindividualmoisturelevelinskin.
Garments are too
damp or too dry after
REDUCE STATIC
• Correctdryingoptionsnot
selected.
• Selectloadweightmanuallybeforestarting
REDUCESTATICoption.
Garments are not
uniformly damp after
EASY IRON
• Numberofgarmentsorload
sizenotproperlyselectedat
thebeginningofthecycle.
• Selectthecorrectnumberorgarmentsorload
sizebeforestartingthecycle.
Water drips from door
during Steam Cycle
• Thisisnormal.
• Condensationwillnormallyformontheinside
ofthedryerdoorduringsteamoperation.Some
condensationmaydripoutthebottomofthedoor.
Steam is not visible
during Steam Cycle
• Thisisnormal.
• Steamvaporisdifculttoseewhenthedooris
closed.However,condensationwillnormallyform
ontheinsideofthedryerdoorifthesteamsystem
isoperatingnormally.
Drum does not turn
during Steam Cycle
• Thisisnormal.
• Thedrumisturnedoffsothatthesteamvapor
remainsinthedrum.Thedrumwillnormallyturn
forabout2secondsonceaminute.
Cannot see steam
vapor at the
beginning of cycle
• Thisisnormal.
• Steamisreleasedatdifferentstagesofthecycle
foreachoption.
• MORETIMEbuttonpressed.
Odors remain in
clothing after
STEAM FRESH
™
• STEAMFRESH
™
didnot
removeodorcompletely.
• Fabricscontainingstrongodorsshouldbe
washedinanormalcycle.
• Thisdisplayindicatesthatthesteamoptionhas
beensetfora“”itemsuchasacomforter.
PresstheLESSTIMEbuttontoreducethe
indicatedloadsize.
FLOW SENSE
indicator light is on
during the drying
cycle
• Ductworkistoolongorhas
toomanyturns/restrictions.
• Signicantblockageofthe
ductworkduetolintbuildup
ordebris.
•Theappliancehasdetected
arestrictionintheexternal
dryerventing.
• Installashorterorstraighterductrun.Seethe
InstallationInstructions.
• Ductworkshouldbechecked/cleanedsoon.
Dryercanbeusedinthiscondition,butdryingtimes
maybelonger.
• IfexhaustrestrictionsaresensedbytheFLOW
SENSEsystem,theindicatorwillremainonfortwo
hoursaftertheendofthecycle.Openingthedooror
pressingthePOWERbuttonwillturnoffthedisplay.
CHECK FILTER light
is on during the
drying cycle
• Lintlterisalmostclogged
orfull.
• Pausethedryingcycleandcleanthelintlter.
The display shows
41