30
General problems with the equipment
Problem
Abnormal water
consumption
Low water
stream from
the jets
No water
stream from
the jets
Noisy pump
and motor
Water leakage
from below
the spa
No airstream
from the jets
Motor does
not work
Black powder
film around
the waterline
It is not possible
to switch of
the spa
Usual cause
•Very strong condensation
and/or splashes
•Running in FILTER mode - slow speed
•Block wall suctions or skimmer
•Dirty filter
•Jets are OFF
•Sliding valves closed
•Pump has airlock
•Adjustable jets switched off
•Power switched off, system off
•Defective pump or motor
•Pump fluctuations
•Sliding valves closed
•Block wall suctions or skimmer
•Low water level.
•Damaged or worn-out motor block
• Check the connections and empty
the hoses
• Air control not open
•Jet spout opening not fixed properly
•Jet spout opening missing
•Power is turned off
•Incorrect or faulty wiring of electrical
supply
•Switch is off
•New turbo/blower brushes
•Spa is trying to heat up
•Spa is in filter cycle
•Spa is in Standard mode
Solution
•Use the cover and refill as necessary
•Select High Speed jets
• Clean the wall suction/skimmer. Remove blockage
• Clean and replace
•Open jets
•Open sliding valves
•See starting to use your spa (page 11)
•Switch on jets
•Reset power
• Contact your dealer
•Low water. Check level on skimmer flap
•Open sliding valves
• Clean the wall suction/skimmer.
•Add water until it reaches the normal water level
• Contact your dealer
• Close or turn off empty cycle if necessary
•Open the control
• Check jet spout openings
• Check jets and replace as necessary
•Reset power
• Contact your dealer
•Auto reset after the motor has cooled down
•Disappears with use
• Check the temperature setting is in Standard mode
•Normal. No adjustment necessary.
• Check setting