EasyManuals Logo
Home>Manitowoc>Ice Maker>NEO UD0140W

Manitowoc NEO UD0140W Technician's Handbook

Manitowoc NEO UD0140W
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Part Number STH042 7/15 35
Step 7 Mix a solution of sanitizer and warm water.
Solution Type Water Mixed With
Sanitizer 3 gal. (12 l) 2 oz (60 ml) sanitizer
Use half of the sanitizer/water solution to sanitize all
removed components. Use a spray bottle to liberally
apply the solution to all surfaces of the removed parts or
soak the removed parts in the sanitizer/water solution.
Do not rinse parts after sanitizing.
Step 8 Use half of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin.
Use a spray bottle to liberally apply the solution. When
sanitizing, pay particular attention to the following areas:
Evaporator plastic parts - including top, bottom and
sides
Bin bottom, sides and top
Do not rinse the sanitized areas.
Step 9 Replace all removed components, wait
10 minutes, then reapply power and water to the ice
machine
Step 10 Press the Clean button. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills, then add the proper amount of ice
machine sanitizer to the water trough.
Model Amount of Sanitizer
U0140 1 ounces (30 ml)
U0190 2 ounces (60 ml)
U0240 2 ounces (60 ml)
U0310 2 ounces (60 ml)
Wait until the sanitize cycle is complete (approximately
22 minutes) then press the Ice button to start ice making.

Table of Contents

Other manuals for Manitowoc NEO UD0140W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc NEO UD0140W and is the answer not in the manual?

Manitowoc NEO UD0140W Specifications

General IconGeneral
BrandManitowoc
ModelNEO UD0140W
CategoryIce Maker
LanguageEnglish

Related product manuals