Step 5 Mix a solution of cleaner and warm water.
Depending on the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Use half of the cleaner/water solution to clean all
components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft bristle brush, sponge or cloth
(not a wire brush) to carefully clean the parts. Soak the
parts for 5 minutes (15 – 20 minutes for heavily scaled
parts). Rinse all components with clean water.
Step 6 While components are soaking, use half of the
cleaner/water solution to clean all foodzone surfaces of
the ice machine and bin. Use a nylon brush or cloth to
thoroughly clean the following ice machine areas:
Evaporator plastic parts – including top, bottom and
sides
Bin bottom, sides and top
Rinse all areas thoroughly with clean water.
Step 7 Mix a solution of sanitizer and warm water.
Use half of the sanitizer/water solution to sanitize all
removed components. Use a spray bottle to liberally
apply the solution to all surfaces of the removed parts or
soak the removed parts in the sanitizer/water solution.
Do not rinse parts after sanitizing.
Step 8 Use half of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and
bin. Use a spray bottle to liberally apply the solution.
When sanitizing, pay particular attention to the following
areas:
Evaporator plastic parts - including top, bottom and
sides
Bin bottom, sides and top
Do not rinse the sanitized areas.
Step 9 Apply food grade lubricant to all o-rings, then
replace all removed components. Wait 10 minutes and
then reapply power and water to the ice machine
Step 10 Press the Clean button. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills, then add the proper amount of ice
machine sanitizer to the water trough.
Wait until the sanitize cycle is complete (approximately
22 minutes) then press the Ice button to start ice making.
Solution Type Water Mixed with
Cleaner 1 gal. (4 l) 16 oz (500 ml) cleaner
Solution Type Water Mixed With
Sanitizer 3 gal. (12 l) 2 oz (60 ml) sanitizer
Model Amount of Sanitizer
U0140 1 ounces (30 ml)
U0190 2 ounces (60 ml)
U0240 2 ounces (60 ml)
U0310 2 ounces (60 ml)

Other manuals for Manitowoc NEO UD0190A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc NEO UD0190A and is the answer not in the manual?

Manitowoc NEO UD0190A Specifications

General IconGeneral
BrandManitowoc
ModelNEO UD0190A
CategoryIce Maker
LanguageEnglish

Related product manuals