Maintenance Section 4
14
Part Number 040001360 6/14
Disassembly
Twist both of the inner tube ends until the tabs line up
with the keyways.
Pull the inner tube ends outward.
F. Remove the Float Valve
Turn the splash shield counterclockwise one or two
turns.
Pull the float valve forward and off the mounting
bracket.
Disconnect the water inlet tube from the float valve at
the compression fitting.
Remove the cap and filter screen for cleaning.
INNER TUBE
TAB
KEYWAY
INNER TUBE
FLOAT VALVE
BRACKET
COMPRESSION
FITTING
CAP AND
FILTER SCREEN
SHUT-OFF VALVE
SPLASH SHIELD
FLOAT